Compression test of c-section cold-formed steel with an opening /

Muhammad Azammuddin Mohd Norman,

Compression test of c-section cold-formed steel with an opening / Muhammad Azammuddin Mohd Norman - xiii, 64 pages : illustrations ; 30 cm. + 1 CD-ROM

Faculty of Civil Engineering and Earth Resources

Project Paper (Bachelors of Civil Engineering) -- Universiti Malaysia Pahang – 2019

Includes bibliographical references

Single sections are the first choice before built-up sections used to resist load induced in a structure for example roof trusses. An existence of perforation in the structural member can be benefit to mechanical and electrical works, aside from that, theoretically the ultimate strength of the structure will be reduce due to existence of openings. This paper presents a detailed description of an experimental study of the flexural buckling strength in the presence of a perforation of cold-formed steel column. A total of 8 short columns, each length 600 mm, vary in size (203 mm and 103 mm) and thickness (1.3 mm and 2.0 mm). Compression test were done by using Universal Testing Machine and the ultimate strength were observed. The test result of 4 specimens with an opening were compared to the ones without opening. The result is presented in three section which are load vs vertical displacement, load vs horizontal displacement and buckling behaviour.

THE0008633(Local)


Faculty of Civil Engineering and Earth Resources--Dissertations


Universities and colleges--Disertations
Theses

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us