MARC details
| 000 -LEADER |
| fixed length control field |
02871ntm a2200349 i 4500 |
| 003 - CONTROL NUMBER IDENTIFIER |
| control field |
MY-KuUP |
| 005 - DATE AND TIME OF LATEST TRANSACTION |
| control field |
20260414172315.0 |
| 006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS |
| fixed length control field |
t||||fr|||| 000 0 |
| 007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION |
| fixed length control field |
ta |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
| fixed length control field |
260115t20252025my a|||fr|||| 000 0 eng d |
| 020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
| International Standard Book Number |
THE0010278 (Local) |
| Qualifying information |
Hardback |
| 040 ## - CATALOGING SOURCE |
| Original cataloging agency |
UMPSA |
| Language of cataloging |
eng |
| Transcribing agency |
UMPSA |
| Description conventions |
rda |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) |
FIST .A45 2025 r Bc. |
| 100 0# - MAIN ENTRY--PERSONAL NAME |
| Personal name |
Muhammad Amiruddin Bin Shuhairi, |
| Relator term |
author. |
| 245 10 - TITLE STATEMENT |
| Title |
Inhalation risk of teachers to airborne microplastics exposure in indoor daycare centre / |
| Statement of responsibility, etc. |
Muhammad Amiruddin Bin Shuhairi |
| 264 ## - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE |
| Place of production, publication, distribution, manufacture |
Kuantan, Pahang : |
| Name of producer, publisher, distributor, manufacturer |
UMPSA, |
| Date of production, publication, distribution, manufacture, or copyright notice |
2025 |
| 264 ## - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE |
| Date of production, publication, distribution, manufacture, or copyright notice |
© 2025 |
| 300 ## - PHYSICAL DESCRIPTION |
| Extent |
xii, 87 pages : |
| Other physical details |
illustrations ; |
| 336 ## - CONTENT TYPE |
| Source |
rdacontent |
| Content type term |
text |
| 337 ## - MEDIA TYPE |
| Source |
rdamedia |
| Media type term |
unmediated |
| 338 ## - CARRIER TYPE |
| Source |
rdacarrier |
| Carrier type term |
volume |
| 347 ## - DIGITAL FILE CHARACTERISTICS |
| Source |
rda |
| File type |
text file |
| Encoding format |
PDF |
| 500 ## - GENERAL NOTE |
| General note |
Faculty of Industrial Sciences and Technology |
| 502 ## - DISSERTATION NOTE |
| Dissertation note |
Final Year Report (Bachelor of Occupational Safety and Health ) -- Universiti Malaysia Pahang Al-Sultan Abdullah - 2025 |
| 504 ## - BIBLIOGRAPHY, ETC. NOTE |
| Bibliography, etc. note |
Include bibliographical reference |
| 520 3# - SUMMARY, ETC. |
| Summary, etc. |
The study addressed the problem of exposure to airborne microplastics (AMPs) in daycare centers, highlighting the potential health risks for teachers due to insufficient data on their presence. The research aimed to determine the concentration of MPs in indoor air, identify their I/O ratios, and explore the correlation between various factors influencing MP concentrations. Nine samples were collected from three daycare centres which located in Kuantan District, Pahang, the concentration of indoor AMP is markedly higher than the outdoor AMP where Daycare Centre B accounted for 89.79 MP/m3 (74.69- 109.17) MP/m3 indoor and 86.88 MP/m3 (69.38-90.10) MP/m3 outdoor and Daycare Centre C with median (IQR) indoor and outdoor AMP concentration was 161.88 (123.44-170.63) MP/m3 and 112.71 (81.56-121.25) MP/m3. The analysis revealed an average indoor-to-outdoor ratio of 1, indicating higher levels of MPs indoors than outdoor environments. Additionally, no significant correlations (p > 0.05) were found between indoor MP concentrations and driving factors (indoor air velocity, indoor temperature, indoor relative humidity, number of occupants, type of building, type of ventilation EDI ranges from 136.54 to 278.69 MP/kg-day. There is an inverse relationship between teacher bodyweight and EDI. The study concluded that daycare centers are critical environments for monitoring AMP exposure, emphasizing the need for improved air quality standards to protect teachers from developing chronic respiratory problems from prolonged exposure |
| 610 20 - SUBJECT ADDED ENTRY--CORPORATE NAME |
| Corporate name or jurisdiction name as entry element |
Faculty of Industrial Sciences and Technology |
| General subdivision |
Dissertations |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Universities and colleges |
| General subdivision |
Dissertations |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Final Year Report |
| General subdivision |
Dissertations |
| 856 ## - ELECTRONIC LOCATION AND ACCESS |
| Uniform Resource Identifier |
http://umpir.ump.edu.my/id/eprint/45535 |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) |
| Source of classification or shelving scheme |
Library of Congress Classification |
| Koha item type |
Final Year Report |