MARC details
| 000 -LEADER |
| fixed length control field |
02767ntm a2200349 i 4500 |
| 003 - CONTROL NUMBER IDENTIFIER |
| control field |
MY-KuUP |
| 005 - DATE AND TIME OF LATEST TRANSACTION |
| control field |
20260119142538.0 |
| 006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS |
| fixed length control field |
t||||fr|||| 000 0 |
| 007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION |
| fixed length control field |
ta |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
| fixed length control field |
260119t20252025my a|||fs|||| 000 0 eng d |
| 020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
| International Standard Book Number |
THE0010280 (Local) |
| Qualifying information |
Hardback |
| 040 ## - CATALOGING SOURCE |
| Original cataloging agency |
UMPSA |
| Language of cataloging |
eng |
| Transcribing agency |
UMPSA |
| Description conventions |
rda |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) |
FIST .A365 2025 r Bc. |
| 100 1# - MAIN ENTRY--PERSONAL NAME |
| Personal name |
Ainin Sofiya Binti Sarif, |
| Relator term |
author. |
| 245 10 - TITLE STATEMENT |
| Title |
Indoor environment at university dormitories: |
| Remainder of title |
association with respiratory and dermal disease among students / |
| Statement of responsibility, etc. |
Ainin Sofiya Binti Sarif |
| 264 #1 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE |
| Place of production, publication, distribution, manufacture |
Kuantan, Pahang : |
| Name of producer, publisher, distributor, manufacturer |
UMPSA, |
| Date of production, publication, distribution, manufacture, or copyright notice |
2025 |
| 264 #4 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE |
| Date of production, publication, distribution, manufacture, or copyright notice |
© 2025 |
| 300 ## - PHYSICAL DESCRIPTION |
| Extent |
xi, 71 pages : |
| Other physical details |
illustrations ; |
| 336 ## - CONTENT TYPE |
| Source |
rdacontent |
| Content type term |
text |
| 337 ## - MEDIA TYPE |
| Source |
rdamedia |
| Media type term |
unmediated |
| 338 ## - CARRIER TYPE |
| Source |
rdacarrier |
| Carrier type term |
volume |
| 347 ## - DIGITAL FILE CHARACTERISTICS |
| Source |
rda |
| File type |
text file |
| Encoding format |
PDF |
| 500 ## - GENERAL NOTE |
| General note |
Faculty of Industrial Sciences and Technology |
| 502 ## - DISSERTATION NOTE |
| Dissertation note |
Final Year Report (Bachelor of Occupational Safety and Health ) -- Universiti Malaysia Pahang Al-Sultan Abdullah - 2025 |
| 504 ## - BIBLIOGRAPHY, ETC. NOTE |
| Bibliography, etc. note |
Include bibliographical reference |
| 520 3# - SUMMARY, ETC. |
| Summary, etc. |
Mold in university dorms can have a severe adverse impact on residents' health by causing respiratory and dermal conditions like eczema and phlegm production. This study examines the relationship between the prevalence of respiratory and dermatological disorders among students at Universiti Malaysia Pahang Al-Sultan Abdullah (UMPSA) and the indoor environment of university dorms. Data were gathered from 150 respondents using a crosssectional approach using surveys and the Dampness and Mold Assessment Tool (DMAT). The most often reported respiratory symptom was wheezing (28.7%), and the least common was chest pain (14%). Mold and dry air were found to be significant predictors of respiratory symptoms using logistic regression analysis. While dry air increased the chance of producing phlegm (OR = 2.680, 95% CI = 1.113–6.453), mold exposure significantly raised the probability of coughing (OR = 3.597, 95% CI = 1.450–8.923), and phlegm (OR = 2.567, 95% CI = 1.071–6.149). A total of 64.1% (Nagelkerke R 2 ) of the variation in respiratory symptoms was explained by the logistic regression model. These results highlight how crucial it is to address interior environmental issues like mold and air quality in order to lower health risks and enhance the well-being of people in dorms. To reduce the symptoms among students, it is recommended to maintain regular maintenance and inspections of the dormitory building. |
| 610 20 - SUBJECT ADDED ENTRY--CORPORATE NAME |
| Corporate name or jurisdiction name as entry element |
Faculty of Industrial Sciences and Technology |
| General subdivision |
Dissertations |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Universities and colleges |
| General subdivision |
Dissertations |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Final Year Report |
| General subdivision |
Dissertations |
| 856 ## - ELECTRONIC LOCATION AND ACCESS |
| Uniform Resource Identifier |
http://umpir.ump.edu.my/id/eprint/45539 |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) |
| Source of classification or shelving scheme |
Library of Congress Classification |
| Koha item type |
Final Year Report |