Characterization, occupational exposure, and respiratory symptoms of airborne microplastics among manufacturing workers / (Record no. 105476)

MARC details
000 -LEADER
fixed length control field 03102ntm a2200349 i 4500
003 - CONTROL NUMBER IDENTIFIER
control field MY-KuUP
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20260812181413.0
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS
fixed length control field t|||||r|||| 000 0
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION
fixed length control field ta
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 260812t20252025my a|||fr|||| 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0010970 (Local)
Qualifying information Hardback
040 ## - CATALOGING SOURCE
Original cataloging agency UMPSA
Language of cataloging eng
Transcribing agency UMPSA
Description conventions rda
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) FSTI .D45 2025 r Bc.
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Dhia Batrisyia Binti Ahmad Fuad, , ,
Relator term author.
245 10 - TITLE STATEMENT
Title Characterization, occupational exposure, and respiratory symptoms of airborne microplastics among manufacturing workers /
Statement of responsibility, etc. Dhia Batrisyia Binti Ahmad Fuad
264 #1 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE
Place of production, publication, distribution, manufacture Kuantan, Pahang :
Name of producer, publisher, distributor, manufacturer UMPSA,
Date of production, publication, distribution, manufacture, or copyright notice 2025
264 #4 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE
Date of production, publication, distribution, manufacture, or copyright notice © 2025
300 ## - PHYSICAL DESCRIPTION
Extent xiv, 126 pages :
Other physical details illustrations ;
336 ## - CONTENT TYPE
Source rdacontent
Content type term text
337 ## - MEDIA TYPE
Source rdamedia
Media type term unmediated
338 ## - CARRIER TYPE
Source rdacarrier
Carrier type term volume
347 ## - DIGITAL FILE CHARACTERISTICS
Source rda
File type text file
Encoding format PDF
500 ## - GENERAL NOTE
General note Faculty of Industrial Sciences and Technology
502 ## - DISSERTATION NOTE
Dissertation note Final Year Report (Bachelor Degree Of Occupational Safety And Health) -- Universiti Malaysia Pahang Al-Sultan Abdullah - 2025
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Include bibliographical reference
520 3# - SUMMARY, ETC.
Summary, etc. Plastic manufacturing workers are continuously exposed to airborne microplastics (AMPs), which may contribute to respiratory health issues due to long term microplastics inhalation. This study aimed to investigate the concentration and characteristics of AMPs and their association with respiratory symptoms among exposed and control groups of workers in a plastic manufacturing facility. Air sampling was conducted using single-stage impactors over three days at three workplace locations, Machine 13 & 14 (Point A), Machine 7 & 8 (Point B), and the Office (Point C) resulting in 27 samples, while respiratory data were collected from 50 participants (34 exposed, 16 control) using the validated American Thoracic Society ATS-DLD-78A questionnaire. Results showed the highest AMP concentration at Point A with (2706.7±668.4 particles/m³), followed by the Office (2295.6±336.7 particles/m³) and Point B (1593.3±626.3 particles/m³). Microplastics were predominantly black (up to 75.91%) and fragmented (over 92%), with mostly sized between 10–100 μm. Binary logistic regression showed no significant association between AMP concentration and symptoms such as cough or phlegm (p > 0.3), but breathlessness was significantly more prevalent in the control group (31.3%) compared to the exposed group (2.9%) (p=0.010). In conclusion, although most respiratory symptoms did not show a significant link to AMP exposure, the detection of AMPs in low-exposure areas and the increase breathlessness in control workers suggest that multifaced indoor air factors may influence respiratory health. This study recommends the implementation of proactive monitoring and improved air control measures to support Malaysia’s OSH MP 2021–2025 and SDG 3.
610 20 - SUBJECT ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Faculty of Industrial Sciences and Technology
General subdivision Dissertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Universities and colleges
General subdivision Dissertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Theses
General subdivision Dissertations
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier https://umpir.ump.edu.my/id/eprint/46290
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Library of Congress Classification
Koha item type Final Year Report
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Permanent Location Current Location Date acquired Total Checkouts Full call number Barcode Date last seen Price effective from Koha item type
  Not lost Library of Congress Classification     UMPLIB GAMBANG UMPLIB GAMBANG 12/08/2026   FSTI .D45 2025 r Bc. T000003805 12/08/2026 12/08/2026 Final Year Report

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us