MARC details
| 000 -LEADER |
| fixed length control field |
03102ntm a2200349 i 4500 |
| 003 - CONTROL NUMBER IDENTIFIER |
| control field |
MY-KuUP |
| 005 - DATE AND TIME OF LATEST TRANSACTION |
| control field |
20260812181413.0 |
| 006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS |
| fixed length control field |
t|||||r|||| 000 0 |
| 007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION |
| fixed length control field |
ta |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
| fixed length control field |
260812t20252025my a|||fr|||| 000 0 eng d |
| 020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
| International Standard Book Number |
THE0010970 (Local) |
| Qualifying information |
Hardback |
| 040 ## - CATALOGING SOURCE |
| Original cataloging agency |
UMPSA |
| Language of cataloging |
eng |
| Transcribing agency |
UMPSA |
| Description conventions |
rda |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) |
FSTI .D45 2025 r Bc. |
| 100 0# - MAIN ENTRY--PERSONAL NAME |
| Personal name |
Dhia Batrisyia Binti Ahmad Fuad, , , |
| Relator term |
author. |
| 245 10 - TITLE STATEMENT |
| Title |
Characterization, occupational exposure, and respiratory symptoms of airborne microplastics among manufacturing workers / |
| Statement of responsibility, etc. |
Dhia Batrisyia Binti Ahmad Fuad |
| 264 #1 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE |
| Place of production, publication, distribution, manufacture |
Kuantan, Pahang : |
| Name of producer, publisher, distributor, manufacturer |
UMPSA, |
| Date of production, publication, distribution, manufacture, or copyright notice |
2025 |
| 264 #4 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE |
| Date of production, publication, distribution, manufacture, or copyright notice |
© 2025 |
| 300 ## - PHYSICAL DESCRIPTION |
| Extent |
xiv, 126 pages : |
| Other physical details |
illustrations ; |
| 336 ## - CONTENT TYPE |
| Source |
rdacontent |
| Content type term |
text |
| 337 ## - MEDIA TYPE |
| Source |
rdamedia |
| Media type term |
unmediated |
| 338 ## - CARRIER TYPE |
| Source |
rdacarrier |
| Carrier type term |
volume |
| 347 ## - DIGITAL FILE CHARACTERISTICS |
| Source |
rda |
| File type |
text file |
| Encoding format |
PDF |
| 500 ## - GENERAL NOTE |
| General note |
Faculty of Industrial Sciences and Technology |
| 502 ## - DISSERTATION NOTE |
| Dissertation note |
Final Year Report (Bachelor Degree Of Occupational Safety And Health) -- Universiti Malaysia Pahang Al-Sultan Abdullah - 2025 |
| 504 ## - BIBLIOGRAPHY, ETC. NOTE |
| Bibliography, etc. note |
Include bibliographical reference |
| 520 3# - SUMMARY, ETC. |
| Summary, etc. |
Plastic manufacturing workers are continuously exposed to airborne microplastics (AMPs), which may contribute to respiratory health issues due to long term microplastics inhalation. This study aimed to investigate the concentration and characteristics of AMPs and their association with respiratory symptoms among exposed and control groups of workers in a plastic manufacturing facility. Air sampling was conducted using single-stage impactors over three days at three workplace locations, Machine 13 & 14 (Point A), Machine 7 & 8 (Point B), and the Office (Point C) resulting in 27 samples, while respiratory data were collected from 50 participants (34 exposed, 16 control) using the validated American Thoracic Society ATS-DLD-78A questionnaire. Results showed the highest AMP concentration at Point A with (2706.7±668.4 particles/m³), followed by the Office (2295.6±336.7 particles/m³) and Point B (1593.3±626.3 particles/m³). Microplastics were predominantly black (up to 75.91%) and fragmented (over 92%), with mostly sized between 10–100 μm. Binary logistic regression showed no significant association between AMP concentration and symptoms such as cough or phlegm (p > 0.3), but breathlessness was significantly more prevalent in the control group (31.3%) compared to the exposed group (2.9%) (p=0.010). In conclusion, although most respiratory symptoms did not show a significant link to AMP exposure, the detection of AMPs in low-exposure areas and the increase breathlessness in control workers suggest that multifaced indoor air factors may influence respiratory health. This study recommends the implementation of proactive monitoring and improved air control measures to support Malaysia’s OSH MP 2021–2025 and SDG 3. |
| 610 20 - SUBJECT ADDED ENTRY--CORPORATE NAME |
| Corporate name or jurisdiction name as entry element |
Faculty of Industrial Sciences and Technology |
| General subdivision |
Dissertations |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Universities and colleges |
| General subdivision |
Dissertations |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Theses |
| General subdivision |
Dissertations |
| 856 ## - ELECTRONIC LOCATION AND ACCESS |
| Uniform Resource Identifier |
https://umpir.ump.edu.my/id/eprint/46290 |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) |
| Source of classification or shelving scheme |
Library of Congress Classification |
| Koha item type |
Final Year Report |