Development of auto re-closer earth leakage circuit breaker (AR-ELCB) / (Record no. 1425)

MARC details
000 -LEADER
fixed length control field 02580nam a2200241 a 4500
001 - CONTROL NUMBER
control field vtls000037586
003 - CONTROL NUMBER IDENTIFIER
control field KUKTEM
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251114204412.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 090610t2008 my a f m 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0006766(Local)
039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE]
Level of rules in bibliographic description 201905290930
Level of effort used to assign nonsubject heading access points amirul
Level of effort used to assign subject headings 201107132229
Level of effort used to assign classification VLOAD
Level of effort used to assign subject headings 200908141627
Level of effort used to assign classification VLOAD
Level of effort used to assign subject headings 200908141601
Level of effort used to assign classification VLOAD
-- 200906101244
-- ida84
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) TK2842 .K43 2008 rs Bc.
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Ahmad Khairul Azwan Jantan Anua Jah
245 10 - TITLE STATEMENT
Title Development of auto re-closer earth leakage circuit breaker (AR-ELCB) /
Statement of responsibility, etc. Ahmad Khairul Azwan Jantan Anua Jah
246 3# - VARYING FORM OF TITLE
Title proper/short title Development of auto re-closer earth leakage circuit breaker (AR-ELCB)
Medium [electronic resource]
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Kuantan, Pahang :
Name of publisher, distributor, etc. UMP,
Date of publication, distribution, etc. 2008
300 ## - PHYSICAL DESCRIPTION
Extent 90 p. :
Other physical details ill. (some col.) ;
Dimensions 30 cm. +
Accompanying material 1 computer disc
502 ## - DISSERTATION NOTE
Dissertation note Project paper (Bachelor of Electrical Engineering (Power system)) -- Universiti Malaysia Pahang - 2008
520 3# - SUMMARY, ETC.
Summary, etc. An Earth Leakage Circuit Breaker (ELCB) is an electrical device that disconnects protected circuit whenever it detects unbalance current between the phase conductor and the neutral conductor. Such an unbalance is sometimes caused by current leakage through the body of a person who is grounded when accidentally touching the energized part of the circuit. A lethal shock can result from these conditions. ELCB are designed to disconnect this fault fast enough to mitigate the harm caused by such shocks. Currently, there is no Earth Leakage Circuit Breaker (ELCB) with auto re-closer features in the market. The current ELCB that available in the market is a manual type and cannot differentiate between temporary disturbances and permanent faults. It’s means that, if a disturbance or fault occurs on the protected area (house or shop), the protection system will force ELCB to trip. One of the drawbacks of the common ELCB is that, it’s can’t turn on the power supply back to the normal operation condition although only a short disturbance occurs. Such disturbance is lightning strike on the transmission line in the distribution site near to the protected area. To turn the power back to normal operation, consumers need to do that manually. To overcome this problem, Auto Re-closer Earth Leakage Circuit Breaker (AR-ELCB) has been developed. This thesis presents the development of AR-ELCB. This device was designed to differentiate between permanent fault and short disturbances (lightning).
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Electric circuit-breakers
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
  Not lost   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   TK2842 .K43 2008 rs Bc. 0000037366 04/09/2019 1 04/09/2019 Final Year Report
  Not lost   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   CD 3247 | TK2842 .K43 2008 rs Bc. 0000037367 04/09/2019 1 04/09/2019 Final Year Report

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us