Process performance evaluation and improvement of an absorption chiller unit / (Record no. 1455)

MARC details
000 -LEADER
fixed length control field 02865nam a2200241 a 4500
001 - CONTROL NUMBER
control field vtls000031360
003 - CONTROL NUMBER IDENTIFIER
control field KUKTEM
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251114204413.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 080903t2008 my a f m 000 0 eng|d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0004777(Local)
039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE]
Level of rules in bibliographic description 201905151132
Level of effort used to assign nonsubject heading access points smfh
Level of effort used to assign subject headings 201107132227
Level of effort used to assign classification VLOAD
Level of effort used to assign subject headings 200908141515
Level of effort used to assign classification VLOAD
Level of effort used to assign subject headings 200908141445
Level of effort used to assign classification VLOAD
-- 200809030914
-- ida84
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) TP496 .B33 2008 rs Thesis
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Badarulnizam Badarullah
245 1# - TITLE STATEMENT
Title Process performance evaluation and improvement of an absorption chiller unit /
Statement of responsibility, etc. Badarulnizam Badarullah
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Kuantan, Pahang :
Name of publisher, distributor, etc. UMP,
Date of publication, distribution, etc. 2008
300 ## - PHYSICAL DESCRIPTION
Extent 31 p. :
Other physical details ill. ;
Dimensions 30 cm.
502 ## - DISSERTATION NOTE
Dissertation note Project paper (Bachelor of Chemical Engineering) --- Universiti Malaysia Pahang - 2008
520 3# - SUMMARY, ETC.
Summary, etc. Absorption refrigeration has a potential to become among the most effective refrigeration unit due to low energy consumption and eco-friendly. However the problem of this unit, it is relatively lower performance compared to the compressor refrigeration unit. In recent years, there are many researchers have studied to improve the absorption chiller unit. For example, instead of single stage absorption chiller being installed, there also have installation for multiple stages of absorption chiller. The purpose of this study is to increase the performance by adding additive in the ammonia/water solution that being used in the absorption refrigeration system. The works were initiated by obtaining and analyzing the process flow diagram (PFD) of the absorption chiller unit. Before process data measurements have been taken, an additive of Zeolite NaA must be prepared. The additive contains of certain chemical such as sodium hydroxide, sodium aluminate and sodium metacilicate. Naturally, the prepared additive is white in color and it is soluble in water. With this characteristic, it is easy to dissolve in the ammonia solution. The additive is added with different concentration in the range of 0.0002 M to 0.001 M. After collecting all the data, data analysis is started. In the experiment, the optimum concentration of additive is determined by referring to the lowest cooling box temperature which will give the lowest value of COP. The optimum concentration of additive that can be added to the absorption process is 0.0006M of Zeolite NaA. The optimum coefficient is 1.5. This coefficient is higher compare to the coefficient of performance for absortion chiller without additive that is 1.2. In future, further improvement of the absorption chiller unit can be done in order to improve its performance such as implementing heat integration design.-Author
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Refrigeration and refrigerating machinery
General subdivision Research
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Refrigeration and refrigerating machinery
General subdivision Valuation
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
  Not lost   Not for loan UMPLIB GAMBANG UMPLIB GAMBANG 04/09/2019   TP496 .B33 2008 rs Thesis 0000031491 04/09/2019 1 04/09/2019 Final Year Report

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us