MARC details
| 000 -LEADER |
| fixed length control field |
02581nam a2200253 a 4500 |
| 001 - CONTROL NUMBER |
| control field |
vtls000025784 |
| 003 - CONTROL NUMBER IDENTIFIER |
| control field |
KUKTEM |
| 005 - DATE AND TIME OF LATEST TRANSACTION |
| control field |
20251114204417.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
| fixed length control field |
080326t2007 my f m 000 0 eng|d |
| 020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
| International Standard Book Number |
THE0006696(Local) |
| 039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE] |
| Level of rules in bibliographic description |
201905171514 |
| Level of effort used to assign nonsubject heading access points |
amirul |
| Level of effort used to assign subject headings |
201107132238 |
| Level of effort used to assign classification |
VLOAD |
| Level of effort used to assign subject headings |
200908141421 |
| Level of effort used to assign classification |
VLOAD |
| Level of effort used to assign subject headings |
200908141353 |
| Level of effort used to assign classification |
VLOAD |
| -- |
200803261700 |
| -- |
kam |
| 040 ## - CATALOGING SOURCE |
| Original cataloging agency |
UMP |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) |
TK1025 .A97 2007 rs Thesis |
| 100 0# - MAIN ENTRY--PERSONAL NAME |
| Personal name |
Mohd Azraie Suarin |
| 245 10 - TITLE STATEMENT |
| Title |
Automatic tester device for earth leakage circuit breaker (ELCB) / |
| Statement of responsibility, etc. |
Mohd Azraie B Suarin |
| 246 3# - VARYING FORM OF TITLE |
| Title proper/short title |
Automatic tester device for earth leakage circuit breaker (ELCB) |
| Medium |
[electronic resource] |
| 260 ## - PUBLICATION, DISTRIBUTION, ETC. |
| Place of publication, distribution, etc. |
Kuantan, Pahang : |
| Name of publisher, distributor, etc. |
UMP, |
| Date of publication, distribution, etc. |
2007 |
| 300 ## - PHYSICAL DESCRIPTION |
| Extent |
82 p. : |
| Other physical details |
ill. (some col.) ; |
| Dimensions |
30 cm. + |
| Accompanying material |
1 computer disc |
| 502 ## - DISSERTATION NOTE |
| Dissertation note |
Project paper (Bachelor of Electrical Engineering (Power systems)) -- Universiti Malaysia Pahang - 2007 |
| 520 1# - SUMMARY, ETC. |
| Summary, etc. |
Power system protection plays important role for the safety of humans and electrical equipments in houses or buildings. Besides it also becomes a precondition of the system for obtaining capability and continuous power supply. Earth leakage circuit breaker (ELCB) is an important protection device especially for houses and buildings. The ELCB’s spring trap will trip to isolate the fault from the system when line to ground fault occurs. So the good condition of the ELCB is very important to run the duty as a power system protector. This project is designed to test the earth leakage circuit breaker (ELCB) automatically every month by detecting current through it when it is in off condition. Microcontroller will be use in this project to make the ELCB automatically tested with programmed it for month. During test period, a current detector which is connected series with the ELCB will detect any current that flow through it. When the detector detect currents, mean that the ELCB does not function properly and LED or buzzer will be ON as an indicator for occupant, so that ELCB can be change immediately. The ELCB is in good condition and can function properly when no current detected and DC motor will be used to switch ON the ELCB’s spring trap. Actually this project can improve the ELCB application and also will enhance the safety for occupant of houses and buildings. -Author |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Electric resistance |
| General subdivision |
Security measures |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Earth resistance |