MARC details
| 000 -LEADER |
| fixed length control field |
02563nam a2200253 a 4500 |
| 001 - CONTROL NUMBER |
| control field |
vtls000038420 |
| 003 - CONTROL NUMBER IDENTIFIER |
| control field |
KUKTEM |
| 005 - DATE AND TIME OF LATEST TRANSACTION |
| control field |
20251114204417.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
| fixed length control field |
090622t2008 my a f m 000 0 eng d |
| 020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
| International Standard Book Number |
THE0006816(Local) |
| 039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE] |
| Level of rules in bibliographic description |
201905291238 |
| Level of effort used to assign nonsubject heading access points |
amirul |
| Level of effort used to assign subject headings |
201107132244 |
| Level of effort used to assign classification |
VLOAD |
| Level of effort used to assign subject headings |
200908141635 |
| Level of effort used to assign classification |
VLOAD |
| Level of effort used to assign subject headings |
200908141609 |
| Level of effort used to assign classification |
VLOAD |
| -- |
200906221245 |
| -- |
kam |
| 040 ## - CATALOGING SOURCE |
| Original cataloging agency |
UMP |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) |
TK3226 .A35 2008 rs Bc. |
| 100 0# - MAIN ENTRY--PERSONAL NAME |
| Personal name |
Wan Mohd Afiq Nazman Wan Anuar |
| 245 10 - TITLE STATEMENT |
| Title |
Study of voltage sag in power system with six-phase transmission line / |
| Statement of responsibility, etc. |
Wan Mohd Afiq Nazman Bin Wan Anuar |
| 246 3# - VARYING FORM OF TITLE |
| Title proper/short title |
Study of voltage sag in power system with six-phase transmission line |
| Medium |
[electronic resource] |
| 260 ## - PUBLICATION, DISTRIBUTION, ETC. |
| Place of publication, distribution, etc. |
Kuantan, Pahang : |
| Name of publisher, distributor, etc. |
UMP, |
| Date of publication, distribution, etc. |
2008 |
| 300 ## - PHYSICAL DESCRIPTION |
| Extent |
58 p. : |
| Other physical details |
ill. ; |
| Dimensions |
30 cm. + |
| Accompanying material |
1 computer disc |
| 502 ## - DISSERTATION NOTE |
| Dissertation note |
Project paper (Bachelor of Electrical Engineering (Power system)) -- Universiti Malaysia Pahang - 2008 |
| 520 ## - SUMMARY, ETC. |
| Summary, etc. |
Voltage sags are the short durations in root-mean-square (RMS) rated AC voltage occur during faults may cause miss-operations to the customer’s equipment and loads of power system and recognized as the most important power quality problem. However, this thesis investigate the sag event which is caused by short circuit (three-phase-to-ground fault and six-phase-to-ground fault) on the double three phase transmission line and conversion of phase double circuit to the six phase single circuit transmission line. Six phase were chosen for this project because six phase enhance power transfer capability and becoming the area of growing interest in the power system industry. This thesis also presents the comparisons between voltage reductions at the terminal bus for both three and six phase cases. Simulation at steady state and transient state of the system proposed is simulated using PSCAD/EMTDC. The system that used in this thesis was four buses transmission line. The simulation result shows that converted double three phase to six phase transmission experienced lower voltage sags level at other bus terminal than double three phase system due to three-phase-to-ground fault and six phase-to-ground fault if the fault happen at bus three, but for faulted bus, the it’s experienced the same percentage voltage sag. For fault happen between transformers in six phase operation, 20% to 45% of the voltage was improve at the faulted bus compare to three phase system. |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Short circuits |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Electric circuits |