MARC details
| 000 -LEADER |
| fixed length control field |
02408nam a2200265 a 4500 |
| 001 - CONTROL NUMBER |
| control field |
vtls000045890 |
| 003 - CONTROL NUMBER IDENTIFIER |
| control field |
KUKTEM |
| 005 - DATE AND TIME OF LATEST TRANSACTION |
| control field |
20251114204420.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
| fixed length control field |
100524t2009 my dao f m 000 0 eng d |
| 020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
| International Standard Book Number |
THE0005672(Local) |
| 039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE] |
| Level of rules in bibliographic description |
201905211103 |
| Level of effort used to assign nonsubject heading access points |
hanafiah |
| Level of effort used to assign subject headings |
201107132244 |
| Level of effort used to assign classification |
VLOAD |
| Level of effort used to assign subject headings |
201103301003 |
| Level of effort used to assign classification |
ida |
| Level of effort used to assign subject headings |
201005311559 |
| Level of effort used to assign classification |
ida |
| -- |
201005241415 |
| -- |
ida |
| 040 ## - CATALOGING SOURCE |
| Original cataloging agency |
UMP |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) |
TA357 .S87 2009 rs Bc. |
| 100 0# - MAIN ENTRY--PERSONAL NAME |
| Personal name |
Suriani Abd Rahman |
| 245 14 - TITLE STATEMENT |
| Title |
The effect of stent void area on hemodynamics in cerebral aneurysm / |
| Statement of responsibility, etc. |
Suriani Binti Abd Rahman |
| 246 3# - VARYING FORM OF TITLE |
| Title proper/short title |
The effect of stent void area on hemodynamics in cerebral aneurysm |
| Medium |
[electronic resource] |
| 260 ## - PUBLICATION, DISTRIBUTION, ETC. |
| Place of publication, distribution, etc. |
Kuantan, Pahang : |
| Name of publisher, distributor, etc. |
UMP, |
| Date of publication, distribution, etc. |
2009 |
| 300 ## - PHYSICAL DESCRIPTION |
| Extent |
xiii, 67 p. : |
| Other physical details |
ill. (some col.) ; |
| Dimensions |
30 cm. + |
| Accompanying material |
1 computer disc |
| 502 ## - DISSERTATION NOTE |
| Dissertation note |
Project paper (Bachelor of Mechanical Engineering) -- Universiti Malaysia Pahang - 2009 |
| 504 ## - BIBLIOGRAPHY, ETC. NOTE |
| Bibliography, etc. note |
Bibliography : p. 58-59 |
| 520 3# - SUMMARY, ETC. |
| Summary, etc. |
The purpose of this study is to develop modeling methodologies to understand how different stent void area alter the aneurysmal flow. Four difference stents design with difference void area were created with suitable geometry for Computational Fluid Dynamics (CFD) analysis. The velocity profile and pressure distribution after installing the device had been identified from the selected stent. These four types of design will be referred as stent type I, II, III, and IV and these stent was tested in an aneurysm model. The simulation of the model was studied under incompressible, Newtonian, viscous, non-pulsatile condition. In this study, we need to determine the correlation between stent porous area and blood flow and to determine the flow behavior in stented aneurysm. We found the stent design affected a cerebral aneurysm hemodynamic. The different of stent structural pattern produces the different results of flow field around the stented aneurysm. The minimum velocity had improved after stents insertion and the type IV with less void area results most optimized. Other than that, the peak pressure will also decrease after the stent implantation. As expected, the lowest peak pressure results from stent type IV. The result shows that the stent with the lowest void area gives the best performance. |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Fluid dynamics |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Hemodynamics |