MARC details
| 000 -LEADER |
| fixed length control field |
02236nam a2200253 a 4500 |
| 001 - CONTROL NUMBER |
| control field |
vtls000045552 |
| 003 - CONTROL NUMBER IDENTIFIER |
| control field |
KUKTEM |
| 005 - DATE AND TIME OF LATEST TRANSACTION |
| control field |
20251114204424.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
| fixed length control field |
100505t2009 my ao f m 000 0 eng d |
| 020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
| International Standard Book Number |
THE0005678(Local) |
| 039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE] |
| Level of rules in bibliographic description |
201905211117 |
| Level of effort used to assign nonsubject heading access points |
hanafiah |
| Level of effort used to assign subject headings |
201108031319 |
| Level of effort used to assign classification |
Fida |
| Level of effort used to assign subject headings |
201107132317 |
| Level of effort used to assign classification |
VLOAD |
| -- |
201005051109 |
| -- |
ida |
| 040 ## - CATALOGING SOURCE |
| Original cataloging agency |
UMP |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) |
TA357.5.F55 A39 2009 rs Bc. |
| 100 0# - MAIN ENTRY--PERSONAL NAME |
| Personal name |
Muhammad Aizat Zuhair Mohd Azly |
| 245 10 - TITLE STATEMENT |
| Title |
Effect of double layer stent to flow phenomena in cerebral aneurysm / |
| Statement of responsibility, etc. |
Muhammad Aizat Zuhair Mohd Azly |
| 246 3# - VARYING FORM OF TITLE |
| Title proper/short title |
Effect of double layer stent to flow phenomena in cerebral aneurysm |
| Medium |
[computer file] |
| 260 ## - PUBLICATION, DISTRIBUTION, ETC. |
| Place of publication, distribution, etc. |
Kuantan, Pahang : |
| Name of publisher, distributor, etc. |
UMP, |
| Date of publication, distribution, etc. |
2009 |
| 300 ## - PHYSICAL DESCRIPTION |
| Extent |
xiv, 66 p. : |
| Other physical details |
ill. (some col.) ; |
| Dimensions |
30 cm. + |
| Accompanying material |
1 computer disc |
| 502 ## - DISSERTATION NOTE |
| Dissertation note |
Project paper (Bachelor of Mechanical Engineering) -- Universiti Malaysia Pahang - 2009 |
| 504 ## - BIBLIOGRAPHY, ETC. NOTE |
| Bibliography, etc. note |
Bibliography : p. 56-57 |
| 520 3# - SUMMARY, ETC. |
| Summary, etc. |
The investigation is about the flow pattern in blood vessel that has been done at the aneurysm with the different type of stent. The velocity profile and the pressure distribution of blood had been identified from the stent implantation. There are three types of stent model in this case study which known as Type 1, Type 2 and Types 3. All types of stent that has been applied to the aneurysm are in double layer. A non-stented and stented aneurysm need be considered for identifying the changes in hemodynamics due to stent implantation. The simulation of the model was studied under incompressible, non-Newtonian, viscous, non-pulsatile condition in which we investigated computationally in a three-dimensional configuration using a fluid dynamics program. The different structure of stent has given the different flow pattern around the aneurysm region. The minimum velocity has been increased after the stent implantation and stent Type 3 has given the optimum result with the low pressure and the highest minimum velocity. Finally, the correlations obtained from this numerical result could be used to investigate the pressure distribution around the diseased segment |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Fluid dynamics |