Effect of double layer stent to flow phenomena in cerebral aneurysm / (Record no. 1762)

MARC details
000 -LEADER
fixed length control field 02236nam a2200253 a 4500
001 - CONTROL NUMBER
control field vtls000045552
003 - CONTROL NUMBER IDENTIFIER
control field KUKTEM
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251114204424.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 100505t2009 my ao f m 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0005678(Local)
039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE]
Level of rules in bibliographic description 201905211117
Level of effort used to assign nonsubject heading access points hanafiah
Level of effort used to assign subject headings 201108031319
Level of effort used to assign classification Fida
Level of effort used to assign subject headings 201107132317
Level of effort used to assign classification VLOAD
-- 201005051109
-- ida
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) TA357.5.F55 A39 2009 rs Bc.
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Muhammad Aizat Zuhair Mohd Azly
245 10 - TITLE STATEMENT
Title Effect of double layer stent to flow phenomena in cerebral aneurysm /
Statement of responsibility, etc. Muhammad Aizat Zuhair Mohd Azly
246 3# - VARYING FORM OF TITLE
Title proper/short title Effect of double layer stent to flow phenomena in cerebral aneurysm
Medium [computer file]
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Kuantan, Pahang :
Name of publisher, distributor, etc. UMP,
Date of publication, distribution, etc. 2009
300 ## - PHYSICAL DESCRIPTION
Extent xiv, 66 p. :
Other physical details ill. (some col.) ;
Dimensions 30 cm. +
Accompanying material 1 computer disc
502 ## - DISSERTATION NOTE
Dissertation note Project paper (Bachelor of Mechanical Engineering) -- Universiti Malaysia Pahang - 2009
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliography : p. 56-57
520 3# - SUMMARY, ETC.
Summary, etc. The investigation is about the flow pattern in blood vessel that has been done at the aneurysm with the different type of stent. The velocity profile and the pressure distribution of blood had been identified from the stent implantation. There are three types of stent model in this case study which known as Type 1, Type 2 and Types 3. All types of stent that has been applied to the aneurysm are in double layer. A non-stented and stented aneurysm need be considered for identifying the changes in hemodynamics due to stent implantation. The simulation of the model was studied under incompressible, non-Newtonian, viscous, non-pulsatile condition in which we investigated computationally in a three-dimensional configuration using a fluid dynamics program. The different structure of stent has given the different flow pattern around the aneurysm region. The minimum velocity has been increased after the stent implantation and stent Type 3 has given the optimum result with the low pressure and the highest minimum velocity. Finally, the correlations obtained from this numerical result could be used to investigate the pressure distribution around the diseased segment
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Fluid dynamics
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
  Not lost   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   CD 4132 | TA357.5.F55 A39 2009 rs Bc. 0000044218 04/09/2019 1 04/09/2019 Final Year Report
  Not lost   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   TA357.5.F55 A39 2009 rs Bc. 0000044217 04/09/2019 1 04/09/2019 Final Year Report

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my