MARC details
| 000 -LEADER |
| fixed length control field |
02362nam a2200277 a 4500 |
| 001 - CONTROL NUMBER |
| control field |
vtls000045762 |
| 003 - CONTROL NUMBER IDENTIFIER |
| control field |
KUKTEM |
| 005 - DATE AND TIME OF LATEST TRANSACTION |
| control field |
20251114204426.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
| fixed length control field |
100513t2009 my a f m 000 0 eng d |
| 020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
| International Standard Book Number |
THE0006242(Local) |
| 039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE] |
| Level of rules in bibliographic description |
201905161217 |
| Level of effort used to assign nonsubject heading access points |
aida |
| Level of effort used to assign subject headings |
201107132319 |
| Level of effort used to assign classification |
VLOAD |
| Level of effort used to assign subject headings |
201005131347 |
| Level of effort used to assign classification |
ida |
| -- |
201005131346 |
| -- |
ida |
| 040 ## - CATALOGING SOURCE |
| Original cataloging agency |
UMP |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) |
TJ260 .K64 2009 rs Bc. |
| 100 1# - MAIN ENTRY--PERSONAL NAME |
| Personal name |
Koh, Kelvin |
| 245 10 - TITLE STATEMENT |
| Title |
Analysis of heat gain against cooling capacity at occupied building / |
| Statement of responsibility, etc. |
Koh Kelvin |
| 246 3# - VARYING FORM OF TITLE |
| Title proper/short title |
Analysis of heat gain against cooling capacity at occupied building |
| Medium |
[electronic resource] |
| 260 ## - PUBLICATION, DISTRIBUTION, ETC. |
| Place of publication, distribution, etc. |
Kuantan, Pahang : |
| Name of publisher, distributor, etc. |
UMP, |
| Date of publication, distribution, etc. |
2009 |
| 300 ## - PHYSICAL DESCRIPTION |
| Extent |
xiv, 64 p. : |
| Other physical details |
ill. (some col.) ; |
| Dimensions |
30 cm. + |
| Accompanying material |
1 computer disc |
| 502 ## - DISSERTATION NOTE |
| Dissertation note |
Project paper (Bachelor of Mechanical Engineering) -- Universiti Malaysia Pahang - 2009 |
| 504 ## - BIBLIOGRAPHY, ETC. NOTE |
| Bibliography, etc. note |
Bibliography : p. 40 |
| 520 3# - SUMMARY, ETC. |
| Summary, etc. |
This project is carried out to indentify whether the existing cooling capacity is suffice for an occupied building. The first objective of this project is to determine the heat gain of Block W when it’s fully occupied. The second objective of this project is to compare the calculated heat gain against the existing cooling capacity. In this project, Block W, UMP was chosen as the case study. The floor plan of Block W is first studied to review the building specifications. The building specification is used in the calculation of heat gain, and therefore to identify the cooling load required for Block W. When Block W is fully occupied, the number of occupant will be around 1500 people. There are two types of air-conditioning system used in Block W which are split unit and air handling unit and the total existing cooling load is observed to be 852.74 kW. The peak heat gain is calculated as 1172.43 kW using Cooling Load Factor/ Cooling Load Temperature Difference (CLF/CLTD) method at 3pm. Therefore, the existing cooling load is observed to be undersized in design. However, the peak heat gain will only happen occasionally throughout the year. In order to overcome the undersized design cooling capacity problem, the cooling capacity should increase 27.3%. |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Heat |
| General subdivision |
Transmission |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Mass transfer |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Air conditioning |