Study of heat transfer coefficient for multi-jet air impinging cooling / (Record no. 1830)

MARC details
000 -LEADER
fixed length control field 03198nam a2200253 a 4500
001 - CONTROL NUMBER
control field vtls000045846
003 - CONTROL NUMBER IDENTIFIER
control field KUKTEM
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251114204427.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 100519t2009 my ao f m 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0006241(Local)
039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE]
Level of rules in bibliographic description 201905161216
Level of effort used to assign nonsubject heading access points aida
Level of effort used to assign subject headings 201107132320
Level of effort used to assign classification VLOAD
-- 201005191621
-- training
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) TJ260 .K49 2009 rs Bc.
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Mohammad Khyru Aris
245 10 - TITLE STATEMENT
Title Study of heat transfer coefficient for multi-jet air impinging cooling /
Statement of responsibility, etc. Mohammad Khyru Bin Aris
246 3# - VARYING FORM OF TITLE
Title proper/short title Study of heat transfer coefficient for multi-jet air impinging cooling
Medium [electronic resource]
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Kuantan, Pahang :
Name of publisher, distributor, etc. UMP,
Date of publication, distribution, etc. 2009
300 ## - PHYSICAL DESCRIPTION
Extent xx, 87 p. :
Other physical details ill. (some col.) ;
Dimensions 30 cm. +
Accompanying material 1 computer disc
502 ## - DISSERTATION NOTE
Dissertation note Project paper (Bachelor of Mechanical Engineering) -- Universiti Malaysia Pahang - 2009
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliography : p. 65
520 3# - SUMMARY, ETC.
Summary, etc. This thesis deals with a study of heat transfer coefficient for multi – jet air impinging cooling. Research and development for enhancement heat transfer using multi – jet air impinging cooling system shows variety possibilities. The required performance must be achieved in other to boost user satisfaction. The main objectives of this thesis are to study the effect of heat transfer coefficient by multi – jet impinging cooling system, and define the relationship between the heat transfer coefficient with the jet flow and the distance from exit nozzle to the heat source. The thesis described the methodology utilize and the result comparison among the jet used. Single, 4, and 9 jet nozzles with constant nozzle diameter, 4 mm were studied in this thesis with different jet flow and also various exit nozzle to heat source spacing. The heat source plate is constant at 100℃. Compressed Air as the coolant medium at room temperature with laminar flow at nozzle exit was studied along with 500, 950, 1960 and 2300 Reynolds numbers. From the results, it is observed that the experiment data using 9 jet array nozzle produced the highest Nusselt number in the range of 95 ℃ to 105 ℃ correspond to low temperature distribution due to many stagnation point formed. This shows the most efficient cooling system. The graph pattern shows the maximum and minimum point in view of the fact that there are many stagnation points. However, the single jet and 4 jet nozzle produced low Nusselt number. The Nusselt number graph trend is linearly decreased for single jet and linearly increased for 4 jet nozzle. The results concluded that the additional number of nozzle with higher Reynolds number and narrow spacing of exit nozzle to heat source plate being used, the more efficient performance produced. More stagnation point created during the impingement on the heat source will produced more effective cooling system. The experiment results are significant to improve the overheat component problem nowadays. The results can also significantly increase the performance of the needed component in order to improve product reliability and customer confidence.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Heat
General subdivision Transmission
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
  Not lost   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   TJ260 .K49 2009 rs Bc. 0000044349 04/09/2019 1 04/09/2019 Final Year Report
  Not lost   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   CD 4198 | TJ260 .K49 2009 rs Bc. 0000044350 04/09/2019 1 04/09/2019 Final Year Report

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us