MARC details
| 000 -LEADER |
| fixed length control field |
03033nam a2200277 a 4500 |
| 001 - CONTROL NUMBER |
| control field |
vtls000045931 |
| 003 - CONTROL NUMBER IDENTIFIER |
| control field |
KUKTEM |
| 005 - DATE AND TIME OF LATEST TRANSACTION |
| control field |
20251114204429.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
| fixed length control field |
100531t2009 my dao f m 000 0 eng d |
| 020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
| International Standard Book Number |
THE0005684(Local) |
| 039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE] |
| Level of rules in bibliographic description |
201905211123 |
| Level of effort used to assign nonsubject heading access points |
hanafiah |
| Level of effort used to assign subject headings |
201107132322 |
| Level of effort used to assign classification |
VLOAD |
| Level of effort used to assign subject headings |
201007141619 |
| Level of effort used to assign classification |
Fida |
| -- |
201005311018 |
| -- |
Fida |
| 040 ## - CATALOGING SOURCE |
| Original cataloging agency |
UMP |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) |
TA357.5 .S53 2009 rs Bc. |
| 100 0# - MAIN ENTRY--PERSONAL NAME |
| Personal name |
Shamsul Aliff Mohd |
| 245 10 - TITLE STATEMENT |
| Title |
Analysis of flow phenomena in stented cerebral aneurysms / |
| Statement of responsibility, etc. |
Shamsul Aliff Bin Mohd |
| 246 3# - VARYING FORM OF TITLE |
| Title proper/short title |
Analysis of flow phenomena in stented cerebral aneurysms |
| Medium |
[electronic resource] |
| 260 ## - PUBLICATION, DISTRIBUTION, ETC. |
| Place of publication, distribution, etc. |
Kuantan, Pahang : |
| Name of publisher, distributor, etc. |
UMP, |
| Date of publication, distribution, etc. |
2009 |
| 300 ## - PHYSICAL DESCRIPTION |
| Extent |
xiv, 79 p. : |
| Other physical details |
ill. (some col.) ; |
| Dimensions |
30 cm. + |
| Accompanying material |
1 computer disc |
| 502 ## - DISSERTATION NOTE |
| Dissertation note |
Project paper (Bachelor of Mechanical Engineering) -- Universiti Malaysia Pahang - 2009 |
| 504 ## - BIBLIOGRAPHY, ETC. NOTE |
| Bibliography, etc. note |
Bibliography : p. 60-63 |
| 520 3# - SUMMARY, ETC. |
| Summary, etc. |
Investigation on the changes of flow phenomena in saccular aneurysms at the Cerebral had been studied. Due to the aneurysms, the stent placement was done to prevent the rupture of aneurysms. The velocity profile and pressure distribution after and before installing the stent had been identified at the different locations of aneurysms. For each location, there is three cases with the different size of aneurysms that are 3.5 mm, 4.5 mm and 5.5 mm in radius. To identify the changes in local hemodynamic due to stent implantation, stented and non stented aneurysm models using selected stent were taken into considerations. The simulation of the model was studied under incompressible, non-Newtonian, viscous, non pulsatile condition in which we investigated computationally in a three-dimensional configuration using a Computational Fluid Dynamics (CFD) program. The minimum velocity had obtained after stents placement. In the first model, the minimum velocity obtained for non stented is 0.374 m/s for case 1, 0.421 m/s for case 2 and 0.36 m/s for case 3. After stenting implementation, the higher minimum velocity were increased for all cases. For case 1 is 0.416 m/s, case 2 is 0.443 m/s and case 3 is 0.404 m/s. In the second model, the minimum velocity for non-stented aneurysms is 0.487 m/s for case 1, 0.424 m/s and 0.343 m/s for case 3. After stenting, the velocity also increased. For case 1 is 0.495 m/s, case is 0.454 m/s and case 3 is 0.382 m/s. The different locations of aneurism, will give the different result of velocity profile and pressure distribution. In the first model, the peak pressure for non-stented aneurysms is 453 Pa and for stented is 422 Pa. While, in second model, for non-stented aneurysms, the peak pressure is 455 Pa and 432 Pa for stented aneurysms. Finally, the correlations obtained from this numerical result could be used to investigate the pressure distribution around the diseased segment. |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Aneurysms |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Intracranial aneurysms |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Fluid dynamics |