Cathodic protection of underground steel pipelines by using sacrificial anodes / (Record no. 1943)

MARC details
000 -LEADER
fixed length control field 03125nam a2200253 a 4500
001 - CONTROL NUMBER
control field vtls000046517
003 - CONTROL NUMBER IDENTIFIER
control field KUKTEM
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251114204431.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 100622t2009 my dao f m 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0006457(Local)
039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE]
Level of rules in bibliographic description 201905141141
Level of effort used to assign nonsubject heading access points amirul
Level of effort used to assign subject headings 201107132329
Level of effort used to assign classification VLOAD
-- 201006221502
-- Fida
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) TJ930 .S25 2009 rs Bc.
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Mohd Saiful Nizam Mohamad
245 10 - TITLE STATEMENT
Title Cathodic protection of underground steel pipelines by using sacrificial anodes /
Statement of responsibility, etc. Mohd Saiful Nizam Bin Mohamad
246 3# - VARYING FORM OF TITLE
Title proper/short title Cathodic protection of underground steel pipelines by using sacrificial anodes
Medium [electronic resource]
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Kuantan, Pahang :
Name of publisher, distributor, etc. UMP ,
Date of publication, distribution, etc. 2009
300 ## - PHYSICAL DESCRIPTION
Extent xvi, 76 p. :
Other physical details ill. (some col.) ;
Dimensions 30 cm. +
Accompanying material 1 computer disc
502 ## - DISSERTATION NOTE
Dissertation note Project paper (Bachelor of Mechanical Engineering) -- Universiti Malaysia Pahang - 2009
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliography : p. 66
520 3# - SUMMARY, ETC.
Summary, etc. Underground corrosion may cause serious damage to the underground steel pipelines structure. Cathodic protection (CP) method is the most important in order to prevent underground corrosion. In this project, Cathodic Protection by using sacrificial anodes technique will be used to the underground steel pipeline. In this project a study of the performance of magnesium and zinc anodes have been carried out. Besides that, in order to know the effect of coating to the corrosion rate, the specimens of steel pipe have been coats using paint. All of the specimens were buried in the soil with depth 0.2m, pH 5.49. Each sample undergoes underground exposure for 28 days before the surface morphology investigation was conducted using Scanning Electron Microscope (SEM). After the exposure period, cleaning process for all specimens follows prior to the final analysis. Corrosion rates were calculated using weight loss methods for all of the specimens. Magnesium sacrificial anode gives better protection to the steel pipe compare to the zinc anode. The result of the corrosion rate for cathodically protected coated steel pipe by using magnesium anode was lowest which is 0.80 mpy compared to the cathodically protected coated steel pipe with sacrificial zinc anode, the corrosion rate is 2.32 mpy. The result for coated steel pipe without using any anode is 2.71 mpy. The magnesium anode performance yield similar result to the cathodicaly protected for uncoated steel pipe. The corrosion rate for coated steel pipe is around 0.80 mpy to 2.71 mpy which is lowest compare to corrosion rate for uncoated steel pipe is around 9.86 mpy to 15.68 mpy. Surface morphology examinations indicate the type of corrosion occurred on the steel pipe was uniform corrosion and galvanic corrosion. In conclusion, the conjoint use of cathodic protection and coating takes advantage of the most attractive features of each method of corrosion control. Magnesium anodes proves to be more practical anode in applying Cathodic Protection for underground steel pipelines.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Pipelines
General subdivision Cathodic protection
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
  Not lost   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   TJ930 .S25 2009 rs Bc. 0000046269 04/09/2019 1 04/09/2019 Final Year Report
  Not lost   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   CD 4435 | TJ930 .S25 2009 rs Bc. 0000046270 04/09/2019 1 04/09/2019 Final Year Report

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us