MARC details
| 000 -LEADER |
| fixed length control field |
02365nam a2200253 a 4500 |
| 001 - CONTROL NUMBER |
| control field |
vtls000058022 |
| 003 - CONTROL NUMBER IDENTIFIER |
| control field |
KUKTEM |
| 005 - DATE AND TIME OF LATEST TRANSACTION |
| control field |
20251114204434.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
| fixed length control field |
111227t2010 my a f m 000 0 eng d |
| 020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
| International Standard Book Number |
THE0003797(Local) |
| 039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE] |
| Level of rules in bibliographic description |
201905151506 |
| Level of effort used to assign nonsubject heading access points |
shah |
| -- |
201112270842 |
| -- |
ida |
| 040 ## - CATALOGING SOURCE |
| Original cataloging agency |
UMP |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) |
TP156.A33 S98 2010 rs Bc. |
| 100 0# - MAIN ENTRY--PERSONAL NAME |
| Personal name |
Nur Syuhada Omar |
| 245 10 - TITLE STATEMENT |
| Title |
Removal of heavy metal in medical institutional wastewater using ultrasonic assisted various leaching solution / |
| Statement of responsibility, etc. |
Nur Syuhada Omar |
| 260 ## - PUBLICATION, DISTRIBUTION, ETC. |
| Place of publication, distribution, etc. |
Kuantan, Pahang : |
| Name of publisher, distributor, etc. |
UMP, |
| Date of publication, distribution, etc. |
2010 |
| 300 ## - PHYSICAL DESCRIPTION |
| Extent |
xii, 45 p. : |
| Other physical details |
ill. (some col.) ; |
| Dimensions |
30 cm. + |
| Accompanying material |
1 CD-ROM |
| 502 ## - DISSERTATION NOTE |
| Dissertation note |
Project paper (Bachelor of of Chemical Engineering) -- Universiti Malaysia Pahang - 2010 |
| 504 ## - BIBLIOGRAPHY, ETC. NOTE |
| Bibliography, etc. note |
Bibliography : p. 31-35 |
| 520 3# - SUMMARY, ETC. |
| Summary, etc. |
Daily, hospital generates a significant amount of wastewater which is more than the consumption of domestic water. The hospital wastewater may contaminate with micro-organisms, heavy metal, toxic chemicals and radioactive elements. In fact, the hospital wastewater is generating hybrid wastewater at the same moment domestic, industrial and effluents of care and medical research. Throughout this research our main concern is to remove targeted heavy metal that found to contain in the hospital wastewater, Pb and Ni. The wastewater will be treated using the ultrasonic technology assisted with several of leaching solution, HNO3, citrate and EDTA. Ultrasonic process has been found as reliable solution which applies intense, high frequency sound to liquids, producing intimate mixing and powerful chemical and physical reactions. The best performance of these leaching solutions (HNO3, citrate and EDTA) will be studied through the main parameter such as type of solution, sonication time and concentration of the solution. The sample obtained from the hospital is filtered and spike with amount of targeted heavy metal prior to ultrasonic process and AAS analysis. As the result, the best time to remove Pb is 3 minutes while 6 minutes for Ni removal. The suitable concentration to remove Pb is 0.06 M while 0.1 M for Ni. The percentage removal is 54% for Pb and 35.93% for Ni. |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Ultrasonic waves |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Sewage |
| General subdivision |
Purification |
| -- |
Heavy metals removal |