Preparation and application of polyaluminium silicate chloride in coagulation process / (Record no. 2053)

MARC details
000 -LEADER
fixed length control field 02190nam a2200241 a 4500
001 - CONTROL NUMBER
control field vtls000058592
003 - CONTROL NUMBER IDENTIFIER
control field KUKTEM
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251114204434.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 120306t2010 my a f m 001 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0003188(Local)
039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE]
Level of rules in bibliographic description 201905161438
Level of effort used to assign nonsubject heading access points zul
-- 201203061306
-- ida
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) TD455 .S45 2010 rs Bc.
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Selvan Murugan
245 10 - TITLE STATEMENT
Title Preparation and application of polyaluminium silicate chloride in coagulation process /
Statement of responsibility, etc. Selvan Murugan
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Kuantan, Pahang :
Name of publisher, distributor, etc. UMP,
Date of publication, distribution, etc. 2010
300 ## - PHYSICAL DESCRIPTION
Extent xi, 54 p. :
Other physical details ill. (some col.) ;
Dimensions 30 cm. +
Accompanying material 1 CD-ROM
502 ## - DISSERTATION NOTE
Dissertation note Project paper (Bachelor of Chemical Engineering) -- Universiti Malaysia Pahang - 2010
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliography : p. 47-48
520 3# - SUMMARY, ETC.
Summary, etc. Coagulation is one of the most important method in chemical treatment of water and wastewater. There are several types of coagulant used in water and wastewater treatment. Most of the inorganic and some polymer coagulants are still not very effective on removing suspended solid and give side effects. A lot of research were done by scientist around the world in coagulation and flocculation field to improve the properties of prepolymerized coagulants, such as polyaluminium chloride (PAC). Recently, Bao-Yu Gao et al.reported that under certain conditions polyaluminum silicate chloride (PASiC), a new type of inorganic polymer coagulant,having a larger particle size and better turbidity removal efficiency than PAC. Coagulation test were done for both water and wastewater PASiC and the results were compared with conventional coagulants (Alum and PAC). For water treatment, PASiC removed 99.45% of turbidity, 68.75% of COD and 48.31% of BOD at optimum coagulant dosage. And for wastewater, it removed 90.14% of turbidity, 89.72% of COD and 46.7%BOD. From this research we can conclude that polyaluminium silicate chloride is very effective in removing suspended solids in both water and wastewater and very good in every aspect compare to other two conventional coagulant, Alum and PAC.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Water
General subdivision Purification
-- Coagulation
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
  Not lost   Not for loan UMPLIB GAMBANG UMPLIB GAMBANG 04/09/2019   TD455 .S45 2010 rs Bc. 0000063062 04/09/2019 1 04/09/2019 Final Year Report
  Not lost   Not for loan UMPLIB GAMBANG UMPLIB GAMBANG 04/09/2019   CD 5806 | TD455 .S45 2010 rs Bc. 0000063063 04/09/2019 1 04/09/2019 Final Year Report

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us