MARC details
| 000 -LEADER |
| fixed length control field |
02595nam a2200253 a 4500 |
| 001 - CONTROL NUMBER |
| control field |
vtls000051683 |
| 003 - CONTROL NUMBER IDENTIFIER |
| control field |
KUKTEM |
| 005 - DATE AND TIME OF LATEST TRANSACTION |
| control field |
20251114204438.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
| fixed length control field |
110307t2010 my a f m 000 0 eng d |
| 020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
| International Standard Book Number |
THE0006255(Local) |
| 039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE] |
| Level of rules in bibliographic description |
201905161433 |
| Level of effort used to assign nonsubject heading access points |
aida |
| Level of effort used to assign subject headings |
201107140036 |
| Level of effort used to assign classification |
VLOAD |
| Level of effort used to assign subject headings |
201103141239 |
| Level of effort used to assign classification |
ida |
| -- |
201103071453 |
| -- |
ida |
| 040 ## - CATALOGING SOURCE |
| Original cataloging agency |
UMP |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) |
TJ263 .R33 2010 rs Bc. |
| 100 0# - MAIN ENTRY--PERSONAL NAME |
| Personal name |
Rabiatuladawiah Kamaruddin |
| 245 10 - TITLE STATEMENT |
| Title |
Design of a small heat exchanger (Shell-and-tube type) / |
| Statement of responsibility, etc. |
Rabiatuladawiah Kamaruddin |
| 246 3# - VARYING FORM OF TITLE |
| Title proper/short title |
Design of a small heat exchanger (Shell-and-tube type) |
| Medium |
[electronic resource] |
| 260 ## - PUBLICATION, DISTRIBUTION, ETC. |
| Place of publication, distribution, etc. |
Kuantan, Pahang : |
| Name of publisher, distributor, etc. |
UMP, |
| Date of publication, distribution, etc. |
2010 |
| 300 ## - PHYSICAL DESCRIPTION |
| Extent |
xiv, 54 p. : |
| Other physical details |
ill. (some col.) ; |
| Dimensions |
30 cm. + |
| Accompanying material |
1 computer disc |
| 502 ## - DISSERTATION NOTE |
| Dissertation note |
Project paper (Bachelor of Mechanical Engineering) -- Universiti Malaysia Pahang - 2010 |
| 504 ## - BIBLIOGRAPHY, ETC. NOTE |
| Bibliography, etc. note |
Bibliography : p. 54 |
| 520 3# - SUMMARY, ETC. |
| Summary, etc. |
This project is mainly focusing on designing one type of a heat exchanger which is shell and tube heat exchanger. Step by step on designing, the software is build first to make the work on calculation easy and simple by using ε-NTU method. This method technically more simple than LMTD where it has to refer to a complex graph to calculate certain outputs that needed. The software used is Visual Basic. The language in the program consists of formulas of calculating parameters in heat exchanger such as heat transfer coefficient, heat transfer rate or heat capacity rate. This program design should match the heat exchanger software in the market. To design this heat exchanger, many considerations were taken. The shell size must be adaptable to the water flow rate. To determine how many tubes that are used also depends on the size of the shell. Water flow rate can be determined by using ball valve opening. The opening is decided to be 50%, 60%, 65%, 75% and 100%. To read the temperature, a thermometer digital is attached at inlet and outlet for both hot and cold fluid. The five readings were taken and take into calculation using the software that has been build. The manual calculation is done to check the program in the software whether it is compatible. From the results obtained, the heat transfer rate rise up when the mass flow rate increased. Lastly the most suitable and economical heat exchanger is decided. And to conclude, the simulation of heat exchanger in the software is compatible with the design as the result is same. |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Heat exchangers |
| General subdivision |
Design and construction |