Performance of solar air-conditioning system using heat pipe evacuated tube collector / (Record no. 2168)

MARC details
000 -LEADER
fixed length control field 02962nam a2200241 a 4500
001 - CONTROL NUMBER
control field vtls000051589
003 - CONTROL NUMBER IDENTIFIER
control field KUKTEM
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251114204438.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 110302t2010 my da f m 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0006027(Local)
039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE]
Level of rules in bibliographic description 201905151149
Level of effort used to assign nonsubject heading access points aida
Level of effort used to assign subject headings 201107140035
Level of effort used to assign classification VLOAD
-- 201103021039
-- Fida
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) TH7687.9 .M34 2010 rs Bc.
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Mahendran Moorthy
245 10 - TITLE STATEMENT
Title Performance of solar air-conditioning system using heat pipe evacuated tube collector /
Statement of responsibility, etc. Mahendran Moorthy
246 3# - VARYING FORM OF TITLE
Title proper/short title Performance of solar air-conditioning system using heat pipe evacuated tube collector
Medium [electronic resource]
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Kuantan, Pahang :
Name of publisher, distributor, etc. UMP,
Date of publication, distribution, etc. 2010
300 ## - PHYSICAL DESCRIPTION
Extent xvi, 109 p. :
Other physical details ill. (some col.) ;
Dimensions 30 cm. + 1 computer disc
502 ## - DISSERTATION NOTE
Dissertation note Project paper (Bachelor of Mechanical Engineering) -- Universiti Malaysia Pahang -- 2010
520 3# - SUMMARY, ETC.
Summary, etc. This is a study on the performance of solar air-conditioning system using heat pipe evacuated tube collector. The objective of this project is to analysis the performance solar air-conditioning system by determining the solar collector efficiency, coefficient of performance (COP) of the absorption chiller, and overall system efficiency and also the electrical energy consumption and operation cost for the system and compare it with the conventional air-conditioning system from the previous case study. The existing solar air-conditioning system is not competitive with electricity driven air-conditioning system because of their high investment and installation cost. Its overall thermal energy conversion efficiency is relatively low, and from an economical point of view, solar cooling and refrigeration are not competitive with the conventional systems. The experiment is conducted at Solar District Cooling Sdn. Bhd and data collected from building automation system for 30 days from 1st-30th June 2010. The data analysed using the theoretical analysis and plotted in graph to discuss about it. The solar collector efficiency varies from 50 to 80% during day time and stored energy can be used during night time. The COP varies from 2.961-2.966 and the overall system efficiency is from 30 to 50%. The investment cost is higher and electrical consumption is relatively lower than conventional air-conditioning system. The economical view is profitable after 18 years and 7 months of installation and environmental view is green energy without pollution. Although all the above findings refer to a particular application in Malaysia, the similar results can be obtained in the country with high solar availability. Finally by considering the problem of pollution of the planet due to the burning of fossil fuels the adoption of solar energy to power absorption chillers, even with marginal economic benefits, should not be underestimated.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Solar air conditioning
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
  Not lost   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   TH7687.9 .M34 2010 rs Bc. 0000053945 04/09/2019 1 04/09/2019 Final Year Report
  Not lost   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   CD 4988 | TH7687.9 .M34 2010 rs Bc. 0000053946 04/09/2019 1 04/09/2019 Final Year Report

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us