Oil palm biomass conversion to bio-oil through direct fired pyrolysis process / (Record no. 2198)

MARC details
000 -LEADER
fixed length control field 02891nam a2200253 a 4500
001 - CONTROL NUMBER
control field vtls000056229
003 - CONTROL NUMBER IDENTIFIER
control field KUKTEM
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251114204439.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 111122t2010 my a f m 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0004687(Local)
039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE]
Level of rules in bibliographic description 201905131343
Level of effort used to assign nonsubject heading access points smfh
-- 201111221523
-- Fida
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) TP359.B46 Z85 2010 rs Bc.
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Ahmad Zulkhairi Muhamad
245 10 - TITLE STATEMENT
Title Oil palm biomass conversion to bio-oil through direct fired pyrolysis process /
Statement of responsibility, etc. Ahmad Zulkhairi Muhamad
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Kuantan, Pahang :
Name of publisher, distributor, etc. UMP,
Date of publication, distribution, etc. 2010
300 ## - PHYSICAL DESCRIPTION
Extent xviii, 72 p. :
Other physical details ill. (some col.) ;
Dimensions 30 cm. +
Accompanying material 1 computer disc
502 ## - DISSERTATION NOTE
Dissertation note Project paper (Bachelor of Chemical Engineering (Gas Technology)) -- Universiti Malaysia Pahang - 2010
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliography : p. 64-66
520 3# - SUMMARY, ETC.
Summary, etc. The objectives of this study are to investigate the impact different biomasses, Empty Fruit Bunches (EFB) and Palm Kernel Shells (PKS), reaction temperature and air damper setting to the conversion of bio-oil and to determine the compatibility of direct fired reactor used in this system with the electric heated fired used in pyrolysis study worldwide. In this study, pyrolysis of EFB and PKS were investigated by using a direct heated pyrolysis reactor. The comparison of the conversion bio-oil obtained from this two different type of sample were studied. Since, a good EFB samples are very limited, the study of effect on reactor temperature and heating rate to the conversion of bio-oil was investigated by using PKS sample. The reaction temperature examined in this study was varied in the range of 300-500oC. Meanwhile, air damper setting in the range of 2.0-4.0 with a constant fuel setting at 19 mmbar were studied. In addition, the competiveness of the direct heated reactor also was investigated by making the comparison in term of percentage of bio-oil conversion with electric heated reactor used worldwide. For the conversion of bio-oil between EFB and PKS, PKS recorded higher yields of bio-oil compared to EFB. The highest conversions of bio-oil were gained at the reaction temperature of 400oC and air damper setting at 4 respectively. The study of the compatibility of direct fired reactor showed that the direct fired reactor was competitive since the conversion of bio-oil was in the range recorded by the electric heated reactor. This study concluded that the conversion of bio-oil was obtained by using PKS sample at the moderate reactor temperature and highest setting of air damper. This study also determined that the direct fired reactor able to become the new potential alternatives in the pyrolysis process since this kind of reactor is cost, energy and time effective compared to the electric heated reactor.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Biodiesel fuels
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Pyrolysis
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
  Not lost   At Bindery UMPLIB GAMBANG UMPLIB GAMBANG 04/09/2019   TP359.B46 Z85 2010 rs Bc. 0000060286 04/09/2019 1 04/09/2019 Final Year Report
  Not lost   Not for loan UMPLIB GAMBANG UMPLIB GAMBANG 04/09/2019   CD 5531 | TP359.B46 Z85 2010 rs Bc. 0000060287 04/09/2019 1 04/09/2019 Final Year Report

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us