MARC details
| 000 -LEADER |
| fixed length control field |
02329nam a2200253 a 4500 |
| 001 - CONTROL NUMBER |
| control field |
vtls000051848 |
| 003 - CONTROL NUMBER IDENTIFIER |
| control field |
KUKTEM |
| 005 - DATE AND TIME OF LATEST TRANSACTION |
| control field |
20251114204441.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
| fixed length control field |
110310t2010 my a f m 000 0 eng d |
| 020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
| International Standard Book Number |
THE0006252(Local) |
| 039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE] |
| Level of rules in bibliographic description |
201905161430 |
| Level of effort used to assign nonsubject heading access points |
aida |
| Level of effort used to assign subject headings |
201107140037 |
| Level of effort used to assign classification |
VLOAD |
| -- |
201103102153 |
| -- |
ida |
| 040 ## - CATALOGING SOURCE |
| Original cataloging agency |
UMP |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) |
TJ262 .N87 2010 rs Bc. |
| 100 0# - MAIN ENTRY--PERSONAL NAME |
| Personal name |
Nurul Hidayah Abdul Samat |
| 245 10 - TITLE STATEMENT |
| Title |
Study of ground source heat pump as cooling system for local applications/ |
| Statement of responsibility, etc. |
Nurul Hidayah Abdul Samat |
| 246 3# - VARYING FORM OF TITLE |
| Title proper/short title |
Study of ground source heat pump as cooling system for local applications |
| Medium |
[electronic resource] |
| 260 ## - PUBLICATION, DISTRIBUTION, ETC. |
| Place of publication, distribution, etc. |
Kuantan, Pahang : |
| Name of publisher, distributor, etc. |
UMP, |
| Date of publication, distribution, etc. |
2010 |
| 300 ## - PHYSICAL DESCRIPTION |
| Extent |
xiii, 49 p. : |
| Other physical details |
ill. (some col.) ; |
| Dimensions |
30 cm. + |
| Accompanying material |
1 computer file |
| 502 ## - DISSERTATION NOTE |
| Dissertation note |
Project paper (Bachelor of Mechanical Engineering) -- Universiti Malaysia Pahang - 2010 |
| 504 ## - BIBLIOGRAPHY, ETC. NOTE |
| Bibliography, etc. note |
Bibliography : p. 42-43 |
| 520 3# - SUMMARY, ETC. |
| Summary, etc. |
This report describes in detail includes a brief description of the Ground Source Heat Pump as cooling system, concentrating on hole depth and coils length. Besides, the descriptive drawings make this report very easy to understand. The main objective of this report is to determine the suitable hole depth and coils length during Ground Source Heat Pump installation. The hole depth and coils length are determined according to the different type of soil moisture. Every type of soil moisture will give different hole depth and coils length. The parameter of hole depth and coils length are determined through the equation in chapter 3. In chapter 4, there are the result of hole depth and coils length parameter that can be used according to the flow rate of R-134 A and soil moisture. Higher soil moisture will decreasing hole depth and coils length. In addition to these, this report also contains the details regarding the different type of other Ground Source Heat Pump which are used these days. Above all, this report gives a detailed description of closed looped Ground Source Heat Pump. This report will be help for those who wish to understand about the basic working of different Ground Source Heat Pump especially those who wish to study Ground Source Heat Pump as cooling system. |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Heat pumps |