MARC details
| 000 -LEADER |
| fixed length control field |
02202nam a2200265 a 4500 |
| 001 - CONTROL NUMBER |
| control field |
vtls000051872 |
| 003 - CONTROL NUMBER IDENTIFIER |
| control field |
KUKTEM |
| 005 - DATE AND TIME OF LATEST TRANSACTION |
| control field |
20251114204442.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
| fixed length control field |
1103111t2010 my a f m 000 0 eng d |
| 020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
| International Standard Book Number |
THE0005660(Local) |
| 039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE] |
| Level of rules in bibliographic description |
201905171511 |
| Level of effort used to assign nonsubject heading access points |
hanafiah |
| Level of effort used to assign subject headings |
201107140037 |
| Level of effort used to assign classification |
VLOAD |
| -- |
201103111721 |
| -- |
ida |
| 040 ## - CATALOGING SOURCE |
| Original cataloging agency |
UMP |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) |
TA357 .M84 2010 rs Bc. |
| 100 0# - MAIN ENTRY--PERSONAL NAME |
| Personal name |
Muhammad Nor Shakiman |
| 245 10 - TITLE STATEMENT |
| Title |
Simulation on airflow inside the nasal cavity with and without uncinate process / |
| Statement of responsibility, etc. |
Muhammad Nor Shakiman |
| 246 3# - VARYING FORM OF TITLE |
| Title proper/short title |
Simulation on airflow inside the nasal cavity with and without uncinate process |
| Medium |
[electronic resource] |
| 260 ## - PUBLICATION, DISTRIBUTION, ETC. |
| Place of publication, distribution, etc. |
Kuantan, Pahang : |
| Name of publisher, distributor, etc. |
UMP, |
| Date of publication, distribution, etc. |
2010 |
| 300 ## - PHYSICAL DESCRIPTION |
| Extent |
xiv, 57 p. : |
| Other physical details |
ill. (some col.) ; |
| Dimensions |
30 cm. + |
| Accompanying material |
1 computer disc |
| 502 ## - DISSERTATION NOTE |
| Dissertation note |
Project paper (Bachelor of Mechanical Engineering with Manufacturing Engineering) -- Universiti Malaysia Pahang - 2010 |
| 504 ## - BIBLIOGRAPHY, ETC. NOTE |
| Bibliography, etc. note |
Bibliography : p. 50-51 |
| 520 3# - SUMMARY, ETC. |
| Summary, etc. |
Functional Endoscopic Sinus Surgery (FESS) is proposed for people with chronic sinus problems who do not respond to medical therapy. During (FESS) procedure, removal of uncinectomy is necessary. Excision of the uncinate process (UP) is to open the maxillary sinus orifice. The UP is a small structure bone in nasal cavity and it’s located under the middle turbinate membranes. However, some patients have claimed that the (FESS) process has reduces their smelling capabilities and voice impairment. Due to this, this study is focusing the effect of changes airflow pattern after remove the UP. The main objective of this study is to simulate, compare and analyze the flow properties inside the nasal cavity with and without UP. This simulation has been done with 3 different models of nasal cavity. The parameter for this simulation is 0.0075 m3s-1 and 0.015m3s-1 air flow rate at the inlet nostril and ambient pressure at the outlet throat. These simulation show positive result and this indicates that the removal of the UP will result smelling capabilities decrease and voice impairment. |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Fluid dynamics |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Air flow |