Performance evaluation of solar flat plate collector / (Record no. 2284)

MARC details
000 -LEADER
fixed length control field 02757nam a2200241 a 4500
001 - CONTROL NUMBER
control field vtls000051881
003 - CONTROL NUMBER IDENTIFIER
control field KUKTEM
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251114204442.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 110314t2010 my a f m 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0006413(Local)
039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE]
Level of rules in bibliographic description 201905131504
Level of effort used to assign nonsubject heading access points amirul
Level of effort used to assign subject headings 201111230953
Level of effort used to assign classification Fida
Level of effort used to assign subject headings 201107140037
Level of effort used to assign classification VLOAD
-- 201103141004
-- ida
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) TJ812 .N55 2010 rs Bc.
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Nik Mohd Qamarul Shafiq Nik Ahmad Kamil
245 10 - TITLE STATEMENT
Title Performance evaluation of solar flat plate collector /
Statement of responsibility, etc. Nik Mohd Qamarul Shafiq Nik Ahmad Kamil
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Kuantan, Pahang :
Name of publisher, distributor, etc. UMP,
Date of publication, distribution, etc. 2010
300 ## - PHYSICAL DESCRIPTION
Extent xv, 71 p. :
Other physical details ill. (some col.) ;
Dimensions 30 cm.+
Accompanying material 1 computer disc
502 ## - DISSERTATION NOTE
Dissertation note Project paper (Bachelor of Mechanical Engineering) -- Universiti Malaysia Pahang - 2010
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliography : p. 55-56
520 3# - SUMMARY, ETC.
Summary, etc. Flat Plate Collectors (FPC) is widely used for domestic hot-water, space heating/drying and for applications requiring fluid temperature less than 100oC. The absorber plate of the FPC transfers solar energy to liquid flowing in the tubes. The flow can takes place due to thermosyphon effect or by forced convection. However, certain energy absorbed by the plate is lost to atmosphere due to higher temperature of the plate. The collector efficiency is dependent on the temperature of the plate which in turn is dependent on the nature of flow of fluid inside the tube, solar insolation, ambient temperature, top loss coefficient, the emissivity of the plate and glass cover, slope, etc. The objective of the present work is to determine the influence of the emissivity of the absorber surface, ambient temperature, spacing between the glass cover and the absorber surface on efficiency of flat plate collector. The influence of operating parameters on flat plate collector is numerical studied. Methods to reduce the losses and compare with the performance of evacuated tube collector (ETC) are proposed by using FORTRAN software. Related equations from previous researcher have been included in the FORTRAN coding the get the data. The influence of the emissivity of the absorber surface, ambient temperature spacing between absorber plate and the glass cover on convection heat transfer coefficient, the overall top loss coefficient are theoretically estimated. The overall top loss coefficient on the flat plate collector is also theoretically determined. It can be observed that the top loss coefficient for the flat plate collector where is between 2.59 Wm-2K-1 until 3.87 Wm-2K-1 while for the evacuated tube collector is 0.7 Wm-2K-1 until 1.04 Wm-2K-1, when the plate temperature is 300K until 350K.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Solar collectors
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
  Not lost   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   TJ812 .N55 2010 rs Bc. 0000053839 04/09/2019 1 04/09/2019 Final Year Report
  Not lost   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   CD 4935 | TJ812 .N55 2010 rs Bc. 0000053840 04/09/2019 1 04/09/2019 Final Year Report

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us