MARC details
| 000 -LEADER |
| fixed length control field |
02665nam a2200265 a 4500 |
| 001 - CONTROL NUMBER |
| control field |
vtls000045995 |
| 003 - CONTROL NUMBER IDENTIFIER |
| control field |
KUKTEM |
| 005 - DATE AND TIME OF LATEST TRANSACTION |
| control field |
20251114204453.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
| fixed length control field |
100607t2009 my a f m 000 0 eng d |
| 020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
| International Standard Book Number |
THE0003490(Local) |
| 020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
| International Standard Book Number |
THE0003491(Local) |
| 039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE] |
| Level of rules in bibliographic description |
201905151206 |
| Level of effort used to assign nonsubject heading access points |
irma |
| Level of effort used to assign subject headings |
201107132214 |
| Level of effort used to assign classification |
VLOAD |
| Level of effort used to assign subject headings |
201006071021 |
| Level of effort used to assign classification |
ida |
| -- |
201006070858 |
| -- |
ida |
| 040 ## - CATALOGING SOURCE |
| Original cataloging agency |
UMP |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) |
TH441 .D59 2009 rs Bc. |
| 100 0# - MAIN ENTRY--PERSONAL NAME |
| Personal name |
Nur Diyana Md. Kasim |
| 245 10 - TITLE STATEMENT |
| Title |
Building defect : |
| Remainder of title |
case study at Taman Seri Indah , Pulau Pinang / |
| Statement of responsibility, etc. |
Nur Diyana Binti Md. Kasim |
| 246 3# - VARYING FORM OF TITLE |
| Title proper/short title |
Building defect : |
| Remainder of title |
case study at Taman Seri Indah , Pulau Pinang |
| Medium |
[electronic resource] |
| 260 ## - PUBLICATION, DISTRIBUTION, ETC. |
| Place of publication, distribution, etc. |
Kuantan, Pahang : |
| Name of publisher, distributor, etc. |
UMP, |
| Date of publication, distribution, etc. |
2009 |
| 300 ## - PHYSICAL DESCRIPTION |
| Extent |
xiv, 89 p. : |
| Other physical details |
ill. (some col.) ; |
| Dimensions |
30 cm. + |
| Accompanying material |
1 computer disc |
| 502 ## - DISSERTATION NOTE |
| Dissertation note |
Project paper (Bachelor of Civil Engineering) -- Universiti Malaysia Pahang - 2009 |
| 504 ## - BIBLIOGRAPHY, ETC. NOTE |
| Bibliography, etc. note |
Bibliography : p. 75-76 |
| 520 3# - SUMMARY, ETC. |
| Summary, etc. |
Malaysia is one of the developing countries and many projects are being implemented. Currently, which some of the projects involve construction of buildings. The construction industry helps to generate the nation’s economy as well as providing benefits to construction companies. But some of these firms acted unprofessionally by involving in projects that do not meet the standard especially in housing development. There are a lot of defects to the houses purchased by house buyers especially in terms of material and workmanship. This study is conducted to identify types of building defect occur in building and to identify causes of building defect occur in building. Besides that, study on building defects which occur at case study area also has been done. The resident satisfactions level on their housing after defect liability period also being analyzed. The study area is located at Taman Seri Indah, Penang. The methodology adopted is through literature review and interview with the developer and house buyers. The data are collected through questionnaire that had been distributed to the parties involve in construction and the house buyers at study area. Types and causes of building defect also can be identified according to survey that has been done to people that involve in construction industry. The results also show the poor workmanship is the major contributor to poor quality of construction. In order to minimize the problem, the contactor has to provide workers with necessary experience and skills. The finding of this study can be used for future references. |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Building failures |