Static and dynamic impact of high voltage direct current (HVDC) in AC power transmission system / (Record no. 2703)

MARC details
000 -LEADER
fixed length control field 02477nam a2200253 a 4500
001 - CONTROL NUMBER
control field vtls000054851
003 - CONTROL NUMBER IDENTIFIER
control field KUKTEM
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251114204457.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 110719t2009 my a f m 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0006807(Local)
039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE]
Level of rules in bibliographic description 201905291147
Level of effort used to assign nonsubject heading access points amirul
Level of effort used to assign subject headings 201107190901
Level of effort used to assign classification Fida
-- 201107190859
-- Fida
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) TK3111 .I79 2009 rs Bc.
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Mohd Irwan Mohd Salleh
245 10 - TITLE STATEMENT
Title Static and dynamic impact of high voltage direct current (HVDC) in AC power transmission system /
Statement of responsibility, etc. Mohd Irwan Mohd Salleh
246 3# - VARYING FORM OF TITLE
Title proper/short title Static and dynamic impact of high voltage direct current (HVDC) in AC power transmission system
Medium [computer file]
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Kuantan, Pahang :
Name of publisher, distributor, etc. UMP,
Date of publication, distribution, etc. 2009
300 ## - PHYSICAL DESCRIPTION
Extent xv, 73 p. :
Other physical details ill. (some col.) ;
Dimensions 30 cm. + 1 computer disc
502 ## - DISSERTATION NOTE
Dissertation note Project paper (Bachelor of Electrical Engineering (Hons.) (Power System)) -- Universiti Malaysia Pahang - 2009
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliography : p. 60
520 3# - SUMMARY, ETC.
Summary, etc. High voltage direct current(HVDC) is very suitable for AC transmitting power over very long distances.It is more economical for long distances of transmitting of transmitting power. Since the cost of an HVDC transmission line is less than that of an AC line with the same capacity, the additional cost of converters for DC transmission is offset when the line is long enough. Studies show that it is advantageous to consider overhead HVDC transmission lines when the transmission distance is longer than 600 km. HVDC lines have no reactance and are capable of transferring more power for the same conductor size than AC lines. DC transmission is especially advantageous when two remotely located large systems are to be connected. The DC transmission tie line acts as an asynchronous link between the two rigid systems eliminating the instability problem inherent in the AC links.This project will determine or analysis the impact of load flow,fault and stability by using Power System Computer Added Design(PSCAD).So,the stability and load flow of the system can be determined.Load flow study are used to ensure that electrical power transfer from generator to consumer through the grid system is stable,reliable and economic.The result from this analysis can be used to make another research related to the power flow which familiar as power system stability analysis
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Electronic power transmission
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
  Not lost   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   TK3111 .I79 2009 rs Bc. 0000058197 04/09/2019 1 04/09/2019 Final Year Report
  Not lost   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   CD 5298 | TK3111 .I79 2009 rs Bc. 0000058198 04/09/2019 1 04/09/2019 Final Year Report

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my