Flow characteristic of an elliptically shaped piezoactuated micropump / (Record no. 2803)

MARC details
000 -LEADER
fixed length control field 03212nam a2200277 a 4500
001 - CONTROL NUMBER
control field vtls000052438
003 - CONTROL NUMBER IDENTIFIER
control field KUKTEM
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251114204500.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 110329t2010 my a f m 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0006432(Local)
039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE]
Level of rules in bibliographic description 201905131523
Level of effort used to assign nonsubject heading access points amirul
Level of effort used to assign subject headings 201110040905
Level of effort used to assign classification Fida
Level of effort used to assign subject headings 201107140041
Level of effort used to assign classification VLOAD
-- 201103291124
-- ida
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) TJ853 .Z36 2010 rs Bc.
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Muhammad Zaim Hassan
245 10 - TITLE STATEMENT
Title Flow characteristic of an elliptically shaped piezoactuated micropump /
Statement of responsibility, etc. Muhammad Zaim Hassan
246 3# - VARYING FORM OF TITLE
Title proper/short title Flow characteristic of an elliptically shaped piezoactuated micropump
Medium [computer file]
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Kuantan, Pahang :
Name of publisher, distributor, etc. UMP,
Date of publication, distribution, etc. 2010
300 ## - PHYSICAL DESCRIPTION
Extent xvii, 76 p. :
Other physical details ill. (some col.) ;
Dimensions 30 cm. +
Accompanying material 1 computer disc
502 ## - DISSERTATION NOTE
Dissertation note Project paper (Bachelor of Mechanical Engineering) -- Universiti Malaysia Pahang - 2010
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliography : p. 65 -66
520 3# - SUMMARY, ETC.
Summary, etc. This project is an outcome of the work carried out in doing and completing final year project, design and analysis flow characteristic of an elliptically shaped piezoactuated micropump. This project is about the investigation of micropump system due to the flowrate of elliptical piezoactuated micro pump. It was started with an introduction in micropump design and structure. This method considers problem regarding valve and valveless types of micropump. After gathering all the relevant information, the project undergoes design process. The design was developed using SOLIDWORK 2010TM software based on the collected data. Several sketches have been made and only one was selected based on the suitability of the micropump and dimension of the nozzle and diffuser and the geometry of the elliptical micropump. The selected sketch was drawn in CAD software and simulates using CFD software. The result from simulation shows the design of micropump is fulfilled. After simulation, the micropump is fabricated. The fabrication is fully follows the specification of the elliptical micropump according to the design of micropump. The purpose of this fabrication is to develop an actual experiment to get the value of volume flowrate of an elliptically shaped of piezoactuated micropump. The result from the experiment shows with the increase of frequency, the volume flowrate also increase. Later on, flow characteristic of an elliptically shaped piezoactuated micropump can be determined. The design of micropump is successful as the investigation of the flow characteristic of an elliptically shaped piezoactuated micropump provides 0.5169μL/s for actuation frequency 25kHz, 0.4898μL/s for actuation frequency 15kHz and 0.4489μL/s for 5kHz actuation frequency. Throughout the investigation, the elliptical micropump is compared to another shape which are circular and square, the velocity through the gap for fluid to flow between membrane of piezoelectric and the body of micropump are be at variance. The micropump considered serves it purpose as it is successfully designed and fabricate.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Fluidic devices
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Piezoelectric materials
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Actuators
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
  Not lost   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   TJ853 .Z36 2010 rs Bc. 0000053993 04/09/2019 1 04/09/2019 Final Year Report
  Not lost   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   CD 5012 | TJ853 .Z36 2010 rs Bc. 0000053994 04/09/2019 1 04/09/2019 Final Year Report

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us