Development of auto re-closer earth leakage circuit breaker for domestic appliances / (Record no. 2867)

MARC details
000 -LEADER
fixed length control field 02337nam a2200241 a 4500
001 - CONTROL NUMBER
control field vtls000055168
003 - CONTROL NUMBER IDENTIFIER
control field KUKTEM
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251114204503.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 110801t2009 my ao f m 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0006768(Local)
039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE]
Level of rules in bibliographic description 201905290931
Level of effort used to assign nonsubject heading access points amirul
-- 201108011441
-- Fida
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) TK2842 .S93 2009 rs Bc.
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Muhammad Syafi'i Ali
245 10 - TITLE STATEMENT
Title Development of auto re-closer earth leakage circuit breaker for domestic appliances /
Statement of responsibility, etc. Muhammad Syafi'i Ali
246 3# - VARYING FORM OF TITLE
Title proper/short title Development of auto re-closer earth leakage circuit breaker for domestic appliances
Medium [computer file]
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Kuantan, Pahang :
Name of publisher, distributor, etc. UMP,
Date of publication, distribution, etc. 2009
300 ## - PHYSICAL DESCRIPTION
Extent xvi, 149 p. :
Other physical details ill. (some col.) ;
Dimensions 30 cm.
502 ## - DISSERTATION NOTE
Dissertation note Project paper (Bachelor of Electrical Engineering (Power System)) -- Universiti Malaysia Pahang - 2009
520 3# - SUMMARY, ETC.
Summary, etc. System protection is the important requirement in electrical power system. The using of protection system can avoid and prevent system from damaged. Electrical energy has caused dangers to human life and machine. Earth leakage circuit breaker (ELCB) is one from protection device that introduced to protect the system. This device is the brain of protection system that monitors input current from power line by it sensor Zero Current Transformer (ZCT), then sending the tripping signal to mechanical switch to disconnected system. ELCB is widely applied by consumer weather is for resident, factory, laboratory and also in power distribution. Because industrial operation requires protection of their Equipment from the lightning, short-circuit and also over-current, so the ELCB will serve the purpose as the protection of their system. This project will focused to improve the ability of current ELCB so that it have ability in identify fault, act accordingly, display the fault(permanent fault and temporary fault) and also re-close it back to normal condition.PIC will execute their instruction when different current from both of current transducer is exceed pre-determine value of sensitivity,100mA. In this project PIC microcontroller will control and operate solid state relay which replacing the application of current mechanical switch.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Electric circuit-breakers
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
  Not lost   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   TK2842 .S93 2009 rs Bc. 0000058375 04/09/2019 1 04/09/2019 Final Year Report
  Not lost   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   CD 5369 | TK2842 .S93 2009 rs Bc. 0000058376 04/09/2019 1 04/09/2019 Final Year Report

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us