MARC details
| 000 -LEADER |
| fixed length control field |
02405nam a2200241 a 4500 |
| 001 - CONTROL NUMBER |
| control field |
vtls000045835 |
| 003 - CONTROL NUMBER IDENTIFIER |
| control field |
KUKTEM |
| 005 - DATE AND TIME OF LATEST TRANSACTION |
| control field |
20251114204505.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
| fixed length control field |
100517t2009 my ao f m 000 0 eng d |
| 020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
| International Standard Book Number |
THE0005649(Local) |
| 039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE] |
| Level of rules in bibliographic description |
201905171504 |
| Level of effort used to assign nonsubject heading access points |
hanafiah |
| Level of effort used to assign subject headings |
201111240951 |
| Level of effort used to assign classification |
Fida |
| Level of effort used to assign subject headings |
201107132319 |
| Level of effort used to assign classification |
VLOAD |
| -- |
201005171613 |
| -- |
ida |
| 040 ## - CATALOGING SOURCE |
| Original cataloging agency |
UMP |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) |
TA357 .H37 2009 rs Bc. |
| 100 0# - MAIN ENTRY--PERSONAL NAME |
| Personal name |
Noor Harliana A. Hamid |
| 245 10 - TITLE STATEMENT |
| Title |
Numerical investigation on the effect of different strut angle to the cerebral aneurysm / |
| Statement of responsibility, etc. |
Noor Harliana A. Hamid |
| 260 ## - PUBLICATION, DISTRIBUTION, ETC. |
| Place of publication, distribution, etc. |
Kuantan, Pahang : |
| Name of publisher, distributor, etc. |
UMP, |
| Date of publication, distribution, etc. |
2009 |
| 300 ## - PHYSICAL DESCRIPTION |
| Extent |
xiii, 71 p. : |
| Other physical details |
ill. (some col.) ; |
| Dimensions |
30 cm. + |
| Accompanying material |
1 computer disc |
| 502 ## - DISSERTATION NOTE |
| Dissertation note |
Project paper (Bachelor of Mechanical Engineering) -- Universiti Malaysia Pahang - 2009 |
| 504 ## - BIBLIOGRAPHY, ETC. NOTE |
| Bibliography, etc. note |
Bibliography : p. [58]-60 |
| 520 3# - SUMMARY, ETC. |
| Summary, etc. |
The objective of this study was to determine the correlation of stent strut angle to blood flow and also to determine the flow behavior in stented aneurysm. The computational fluid dynamics was applied to access the changes of velocity and pressure in aneurysms. For this study, there are five stent with the same design but different in strut angle of the stent. The strut angle used in this study was 30°, 35°, 35°, 40°, 45° and 50°. By using 30° of strut angle as the control model and the other angle as the experimental model, there are referred to as type I, type II, type III and type IV. The simulation of the model was studied under incompressible, Newtonian, viscous and non-pulsatile condition. The results for all stents analyzed in the current study showed that the stent with higher angle are more efficient than stent with lower angle. The minimum velocity increased with the implacement of stent type IV which is the higher strut angle. Meanwhile, for the pressure distribution of all type of stents indicate that lowest peak pressure obtained by stent type III. Therefore, strut angle used should be suitable to satisfy the requirement of lowest peak pressure and highest minimum velocity. So, the strut angle has to be maintained within a certain range, which varies from 40° to 45°. Finally, the correlation obtained from this numerical result could be used to investigate the pressure distribution around the aneurysms. |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Fluid dynamics |