Design of tribometer for joint simulator in biomedical application / (Record no. 2938)

MARC details
000 -LEADER
fixed length control field 03366nam a2200253 a 4500
001 - CONTROL NUMBER
control field vtls000045857
003 - CONTROL NUMBER IDENTIFIER
control field KUKTEM
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251114204505.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 100520t2009 my ao f m 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0006486(Local)
039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE]
Level of rules in bibliographic description 201905141221
Level of effort used to assign nonsubject heading access points amirul
Level of effort used to assign subject headings 201107132320
Level of effort used to assign classification VLOAD
-- 201005201514
-- ida
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) TJ1075 .N35 2009 rs Bc.
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Mohammad Najib Mornie
245 10 - TITLE STATEMENT
Title Design of tribometer for joint simulator in biomedical application /
Statement of responsibility, etc. Mohammad Najib Bin Mornie
246 3# - VARYING FORM OF TITLE
Title proper/short title Design of tribometer for joint simulator in biomedical application
Medium [electronic resource]
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Kuantan, Pahang :
Name of publisher, distributor, etc. UMP,
Date of publication, distribution, etc. 2009
300 ## - PHYSICAL DESCRIPTION
Extent xv, 69 p. :
Other physical details ill. (some col.) ;
Dimensions 30 cm. +
Accompanying material 1 computer disc
502 ## - DISSERTATION NOTE
Dissertation note Project paper (Bachelor of Mechanical Engineering) -- Universiti Malaysia Pahang - 2009
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliography : p. 61-63
520 3# - SUMMARY, ETC.
Summary, etc. This thesis presents a study of application of tribometer as joint simulator for biomedical application and the design of tribometer for joint simulator in orthopaedic implant purpose utilizing both the computer aided design (CAD) software and finite element analysis (FEA) using Solidwork and FEMPRO ALGOR Software. The objectives of this study are to design tribometer for hip joint simulator for biomedical purpose with three different types of bearing combination. In chapter one, the introduction to the tribology are presented. The chapter one gives the first view on how the tribometer can be designed so that the mechanism of the hip can be studied. The chapter two elaborate the theories and concepts according to the scopes of the study. All materials used being discussed in this chapter. Besides, the chapter three is the methodology of the study. The methodology stressed on the steps and methods how to design the tribometer. The most important part in the thesis is the results and discussion. In the chapter four, the results of the tribometer design and the finite element analysis is collected. The results also include the calculation of wear for four different types of materials which are the Stainless Steel, Alumina Al2O3, Ti6Al4V and the Ultra High Molecular Weight Polyethylene UHMWPE. Therefore, this thesis also deals with the analysis of stress at the bearing in term of applied load to the bearing surface with finite element analysis. There are three combinations of bearing involved in this thesis which are metal-on-metal, ceramic-on-metal and polymer-on-metal combinations. The analysis involved four different types of load applied which are 50 N, 100 N, 150 N and 200 N. The results of analysis give the results the maximum stress occurred at the polymer-on metal bearing combination followed by the ceramic-on-metal and the minimum stress occurred at the metal-on-metal bearing combination. The calculation of wear rate realized that the UHMWPE give the highest ware rate which is the polymer, the Stainless Steel which is the metal give the lowest wear rate. The last chapter of this thesis which is chapter five conclude all results. The results give the better understanding at the application of tribometer and the design process in designing the tribometer for joint simulator in biomedical application.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Tribology
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
  Not lost   Not for loan UMPLIB GAMBANG UMPLIB GAMBANG 04/09/2019   CD 4185 | TJ1075 .N35 2009 rs Bc. 0000044324 04/09/2019 1 04/09/2019 Final Year Report
  Not lost   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   TJ1075 .N35 2009 rs Bc. 0000044323 04/09/2019 1 04/09/2019 Final Year Report

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my