Feasibility study of LNG pre-cooling system using carbon dioxide as a refrigerant / (Record no. 2962)

MARC details
000 -LEADER
fixed length control field 02936nam a2200253 a 4500
001 - CONTROL NUMBER
control field vtls000058149
003 - CONTROL NUMBER IDENTIFIER
control field KUKTEM
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251114204506.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 120105t2011 my a f m 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0004776(Local)
039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE]
Level of rules in bibliographic description 201905151130
Level of effort used to assign nonsubject heading access points smfh
-- 201201051751
-- ida
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) TP492.8 .N67 2011 rs Bc.
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Norshahida Rahman
245 10 - TITLE STATEMENT
Title Feasibility study of LNG pre-cooling system using carbon dioxide as a refrigerant /
Statement of responsibility, etc. Norshahida Rahman
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Kuantan, Pahang :
Name of publisher, distributor, etc. UMP,
Date of publication, distribution, etc. 2011
300 ## - PHYSICAL DESCRIPTION
Extent xiv, 39 p. :
Other physical details ill. ;
Dimensions 30 cm. +
Accompanying material 1 CD-ROM
502 ## - DISSERTATION NOTE
Dissertation note Project paper (Bachelor of Chemical Engineering (Gas Technology)) -- Universiti Malaysia Pahang - 2011
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliography : p. 36-38
520 3# - SUMMARY, ETC.
Summary, etc. Refrigeration is a process of removing heat from a colder medium. By using the latent heat properties of refrigerant, the heat will be rejecting to a warmer medium. The basic of requirements for the refrigeration are the compressor, chiller, expansion valve and also condenser. In the LNG industry, refrigeration plays a major part. The aims of this research are to compare the difference of refrigerants used in pre-cooling system. The refrigerants that used in this research are propane and carbon dioxide. Another part that must be focused on this research is the refrigerants’ parameters which are most important consideration for approving that the carbon dioxide can be replacing the propane as a refrigerant that can be used soon in pre-cooling loop system. A simple model of propane refrigeration loop is used to create a steady state simulation using Aspen HYSYS 7.0 process simulator. By having a valid data from the propane loop, a simulation can be continued by replacing composition from propane to carbon dioxide. The same model constructed in the loop, but the other conditions must be changed to make it suitable and converged with the new refrigerant. The composition of refrigerant in the loop is still same 1, showing the purification of the component. The result shows the coefficient of performance (COP) for propane is 1.73 and carbon dioxide is 4.78. For the value of compressor duty using carbon dioxide is lower than the original loop, which the value is 96.7808 kW and propane duty is at 162.938 kW. Lastly, in terms of the costing of compressor using carbon dioxide is only at $ 54320 / yr which lower compared to compressor cost for propane is $ 91280 / yr. At this stage, we can conclude that the low duty, make the cost is low and this project will be more save. So, from this research, it can be conclude that it is successful because the main objective for replacing carbon dioxide as refrigerant has been achieved where the COP of carbon dioxide is higher than COP of propane.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Refrigerants
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Carbon dioxide
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
  Not lost   Not for loan UMPLIB GAMBANG UMPLIB GAMBANG 04/09/2019   TP492.8 .N67 2011 rs Bc. 0000060847 04/09/2019 1 04/09/2019 Final Year Report
  Not lost   Not for loan UMPLIB GAMBANG UMPLIB GAMBANG 04/09/2019   CD 5589 | TP492.8 .N67 2011 rs Bc. 0000060848 04/09/2019 1 04/09/2019 Final Year Report

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my