Modeling and performance enhancements of a gas turbine combined cycle power plant / (Record no. 3389)

MARC details
000 -LEADER
fixed length control field 04358nam a2200265 a 4500
001 - CONTROL NUMBER
control field vtls000067520
003 - CONTROL NUMBER IDENTIFIER
control field KUKTEM
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251114204521.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 121207t2012 my a f m 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0006701(Local)
039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE]
Level of rules in bibliographic description 201905171518
Level of effort used to assign nonsubject heading access points amirul
Level of effort used to assign subject headings 201710161610
Level of effort used to assign classification aishah
-- 201212070958
-- Fida
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) TK1076 .T43 2012 rs Thesis
100 1# - MAIN ENTRY--PERSONAL NAME
Personal name Thamir Khalil Ibrahim
245 10 - TITLE STATEMENT
Title Modeling and performance enhancements of a gas turbine combined cycle power plant /
Statement of responsibility, etc. Thamir Khalil Ibrahim
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Kuantan, Pahang :
Name of publisher, distributor, etc. UMP,
Date of publication, distribution, etc. 2012
300 ## - PHYSICAL DESCRIPTION
Extent xxiv, 254 p. :
Other physical details ill. (some col.) ;
Dimensions 30 cm. +
Accompanying material 1 CD-ROM
502 ## - DISSERTATION NOTE
Dissertation note Thesis (Doctor of Philosophy in Mechanical Engineering) -- Universiti Malaysia Pahang - 2012
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliography : p.232-252
520 3# - SUMMARY, ETC.
Summary, etc. This thesis deals with modelling and performance enhancements of a gas-turbine combined cycle power plant. A clean and safe energy is the greatest challenges to meet the requirements of green environment. These requirements given way the long time governing authority of steam turbine (ST) in the world power generation, and gas turbine (GT) and its combined cycle (CCGT) will replace it. Therefore, it is necessary to predict the characteristics of the CCGT system and optimize its operating strategy by developing a simulation system. Several configurations of the GT and CCGT plants systems are proposed by thermal analysis. The integrated model and simulation code for exploiting the performance of gas turbine and CCGT power plant are developed utilizing MATLAB code. New strategies for GT and CCGT power plant's operational modelling and optimizations are suggested for power plant operation, to improve overall performance. The effect of various enhancing strategies on the performance of the CCGT power plant (two-shaft, intercooler, regenerative, reheat, and multi-pressure heat recovery steam generator (HRSG)) based on the real GT and CCGT power plants. An extensive thermodynamic analysis of the modifications of the most common configuration's enhancements has been carried out. The performance code for heavy-duty GT and CCGT power plants are validated with the real power plant of Baiji GT and MARAFIQ CCGT plants the results have been satisfactory. The simulating results show that the reheated GT has a higher power (388MW) while the higher thermal efficiency occurs in the regenerative GT (52%) with optimal pressure ratio and turbine inlet temperature. The performance enhancing strategies results show that the higher power output occurs in the intercooler-reheat GT strategy (404MW). Furthermore, the higher thermal efficiency (56.9%) and lower fuel consumption (0.13kg/kWh) occur in the intercooler-regenerative-reheat GT strategy. The analyses of the HRSG configurations show that the maximum power output (1238MW) occurred in the supplementary triple pressure with reheat CCGT while the overall efficiency was about 56.6%. The intercooler-reheat CCGT strategy has higher power output (1637MW) and the higher overall thermal efficiency (59.4%) and lower fuel consumption (0.047kg/kWh) occur with the regenerative-reheat CCGT strategy. The simulation result shows that the proposed GT system improved 19% of thermal efficiency and 22% of power output. In addition, the proposed CCGT system improved 4.6% of thermal efficiency for and 22.5% of power output. The optimization result shows that the optimum power (1280MW) and the overall thermal efficiency (65%) of the supplementary triple pressure with reheat CCGT. Therefore, the optimization procedure is reasonably accurate and efficient. Thus, the operation conditions and ambient temperature are strongly influenced on the overall performance of the GT and CCGT. The optimum efficiency and power are found at higher turbine inlet temperatures. It can be comprehended that the developed models are powerful tools for estimating the overall performance of the CCGT plants. The energy and exergy analysis models for the GT and CCGT plants are highly recommended for predicting them performance based on inlet air cooling system.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Combined cycle power plants
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Gas power plants
856 40 - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://ecollib.ump.edu.my/3819/">http://ecollib.ump.edu.my/3819/</a>
Public note Library access only
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
  Not lost Library of Congress Classification   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   TK1076 .T43 2012 rs Thesis 0000067904 04/09/2019 1 04/09/2019 Thesis
  Not lost Library of Congress Classification   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   CD 6296 | TK1076 .T43 2012 rs Thesis 0000067905 04/09/2019 1 04/09/2019 Thesis

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us