A study on abnormal pattern recognition using mahalanobis distance for local exhaust ventilation system / (Record no. 3460)

MARC details
000 -LEADER
fixed length control field 02061nam a2200253 a 4500
001 - CONTROL NUMBER
control field vtls000067417
003 - CONTROL NUMBER IDENTIFIER
control field KUKTEM
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251114204523.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 121205t2012 my a f m 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0003539(Local)
039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE]
Level of rules in bibliographic description 201905152021
Level of effort used to assign nonsubject heading access points zulaiha
-- 201212051448
-- Fida
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) TH7674 .H34 2012 rs Bc.
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Nor Hafizah Abd Rauf
245 12 - TITLE STATEMENT
Title A study on abnormal pattern recognition using mahalanobis distance for local exhaust ventilation system /
Statement of responsibility, etc. Nor Hafizah Abd Rauf
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Kuantan, Pahang :
Name of publisher, distributor, etc. UMP,
Date of publication, distribution, etc. 2012
300 ## - PHYSICAL DESCRIPTION
Extent xi,140 p. :
Other physical details ill. ;
Dimensions 30 cm. +
Accompanying material 1 CD-ROM
502 ## - DISSERTATION NOTE
Dissertation note Project paper (Bachelor of Chemical Engineering) -- Universiti Malaysia Pahang - 2012
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliography : p. 24-26
520 3# - SUMMARY, ETC.
Summary, etc. Local Exhaust Ventilation (LEV) systems can afford a very efficient means of exposure control. Ventilation is a practical system for controlling the air quality and thermal exposure that the employees meet. Ventilation can be used to eliminate air contaminant from breathing district of the employees. Local Exhaust Ventilation (LEV) is employ to eliminate contaminants that are generated at a local supply. Air is drawn from a source at a rate competent of eliminating any air contaminants generated at that supply before they can be dispersed into the work surroundings. There is a problem with conventional method in measuring the LEV, which is time consuming. The conventional method is tedious because it takes longer time to measure the LEV. The objective of this research is to introduce new approach of LEV monitoring practice (Mahalanobis Distance recognition). By using Mahalanobis Distance (MD) with Excel Based Programmed, the method in measuring LEV will be easier and faster. It is believe that this new method is one of the first attempts to evaluate LEV performance by using multi-dimensional approach.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Natural ventilation
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Ventilation
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
  Not lost   Not for loan UMPLIB GAMBANG UMPLIB GAMBANG 04/09/2019   TH7674 .H34 2012 rs Bc. 0000068232 04/09/2019 1 04/09/2019 Final Year Report
  Not lost   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   CD 6408 | TH7674 .H34 2012 rs Bc. 0000068233 04/09/2019 1 04/09/2019 Final Year Report

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us