MARC details
| 000 -LEADER |
| fixed length control field |
02265nam a2200253 a 4500 |
| 001 - CONTROL NUMBER |
| control field |
vtls000068144 |
| 003 - CONTROL NUMBER IDENTIFIER |
| control field |
KUKTEM |
| 005 - DATE AND TIME OF LATEST TRANSACTION |
| control field |
20251114204532.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
| fixed length control field |
130121t2012 my a f m 000 0 eng d |
| 020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
| International Standard Book Number |
THE0003541(Local) |
| 039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE] |
| Level of rules in bibliographic description |
201905152023 |
| Level of effort used to assign nonsubject heading access points |
zulaiha |
| Level of effort used to assign subject headings |
201301211235 |
| Level of effort used to assign classification |
Fida |
| -- |
201301211234 |
| -- |
Fida |
| 040 ## - CATALOGING SOURCE |
| Original cataloging agency |
UMP |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) |
TH7674 .H87 2012 rs Bc. |
| 100 0# - MAIN ENTRY--PERSONAL NAME |
| Personal name |
Nuur Husna Hasnin |
| 245 12 - TITLE STATEMENT |
| Title |
A preliminary development of baseline for normal condition of Local Exhaust Ventilaton system (LEV) by using Mahalanobis Distance (MD) method / |
| Statement of responsibility, etc. |
Nuur Husna Hasnin |
| 260 ## - PUBLICATION, DISTRIBUTION, ETC. |
| Place of publication, distribution, etc. |
Kuantan, Pahang : |
| Name of publisher, distributor, etc. |
UMP, |
| Date of publication, distribution, etc. |
2012 |
| 300 ## - PHYSICAL DESCRIPTION |
| Extent |
xiv,32 p. : |
| Other physical details |
ill. ; |
| Dimensions |
30 cm. + |
| Accompanying material |
1 CD-ROM |
| 502 ## - DISSERTATION NOTE |
| Dissertation note |
Project paper (Bachelor of Chemical Engineering) -- Universiti Malaysia Pahang - 2012 |
| 504 ## - BIBLIOGRAPHY, ETC. NOTE |
| Bibliography, etc. note |
Bibliography : p. 27-28 |
| 520 3# - SUMMARY, ETC. |
| Summary, etc. |
Ventilation is the mechanical system in a building that brings in fresh outdoor air and removes the contaminated indoor air. In a workplace, ventilation is used to control exposure to airborne contaminants. It is commonly used to remove contaminants such as fumes, dusts, and vapors, in order to provide a healthy and safe working environment. Therefore, the LEV system is considered as an important system that should have in every single workplace so that all the workers are not exposed to the hazardous. In measuring the LEV systems, the study has come out with a new approach which is Mahalanobis Distance method (MD). It is believe that this new method is one of the first attempts to evaluate local exhaust ventilation performance by using multi-dimensional approach. The previous method of measuring the local exhaust ventilation system is time consuming which means it took a long period of time in order to measure the point. Besides, not all the measuring points give a significant value for the overall performance of local exhaust ventilation systems. The purposed of this study is to develop the preliminary baseline on normal conditions that will be a starting point on solving the time consuming problem on measuring the local exhaust ventilation systems. |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Natural ventilation |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Ventilation |