Frequency domain analysis on acoustic emission signal in bone tissues / (Record no. 3775)

MARC details
000 -LEADER
fixed length control field 02365nam a2200253 a 4500
001 - CONTROL NUMBER
control field vtls000068757
003 - CONTROL NUMBER IDENTIFIER
control field KUKTEM
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251114204534.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 130227t2012 my a f m 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0005823(Local)
039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE]
Level of rules in bibliographic description 201905131530
Level of effort used to assign nonsubject heading access points aida
-- 201302271608
-- Fida
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) TA418.84 .H34 2012 rs Bc.
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Muhammad Hafiz Ramli
245 10 - TITLE STATEMENT
Title Frequency domain analysis on acoustic emission signal in bone tissues /
Statement of responsibility, etc. Muhammad Hafiz Ramli
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Kuantan, Pahang :
Name of publisher, distributor, etc. UMP,
Date of publication, distribution, etc. 2012
300 ## - PHYSICAL DESCRIPTION
Extent xiii, 58 p. :
Other physical details ill. (some col.) ;
Dimensions 30 cm. +
Accompanying material 1 CD-ROM
502 ## - DISSERTATION NOTE
Dissertation note Project paper (Bachelor of Mechanical Engineering) -- Universiti Malaysia Pahang - 2012
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliography : p. 56-57
520 3# - SUMMARY, ETC.
Summary, etc. The purpose of this study is to study acoustic emission signal in bone tissues. The objectives of this research are to determine acoustic emission (AE) signal in different types of bone tissue; hard and soft bone’s tissue and to observe the trend of acoustic emission signal for penetration during pedicle screw fixation procedure. It also to propose a method to help medical practitioner in penetration process during pedicle screw fixation procedure using acoustic emission technique. Generally, the medical practitioner had a hard time while doing the pedicle screw fixation procedure when it involved with cervical spine. The cervical spine is the most complicated articular system in the body because the anatomy of the region which are close to spinal cord. This study would help to monitor the penetration process. For this study, goat vertebras were use as specimen. During pedicle screw fixation procedure, pedicle probe is used to penetrate the specimen and sensor captured the AE signal and recorded data with help of AEWin Software. Using FFT analysis the result show dominant frequency in compact bone is high compare to spongy bone. AE signal also can be measure when pedicle probe penetrated through the interface of the bone tissues during the pedicle screw fixation procedure. In conclusion, AE technique can use for monitoring acoustic emission signal produced by specimen in pedicle screw fixation procedure.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Cervical vertebrae
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Acoustic emission testing
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
  Not lost   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   TA418.84 .H34 2012 rs Bc. 0000069709 04/09/2019 1 04/09/2019 Final Year Report
  Not lost   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   CD 6607 | TA418.84 .H34 2012 rs Bc. 0000069710 04/09/2019 1 04/09/2019 Final Year Report

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us