CFD simulation using fluent to determine the heat transfer coefficient of a packed bed system / (Record no. 3807)

MARC details
000 -LEADER
fixed length control field 01826nam a2200241 a 4500
001 - CONTROL NUMBER
control field vtls000069509
003 - CONTROL NUMBER IDENTIFIER
control field KUKTEM
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251114204535.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 130513t2012 my a f m 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0006244(Local)
039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE]
Level of rules in bibliographic description 201905161220
Level of effort used to assign nonsubject heading access points aida
-- 201305131037
-- Fida
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) TJ260 .L56 2012 rs Bc.
100 1# - MAIN ENTRY--PERSONAL NAME
Personal name Lim, Sing Wee
245 10 - TITLE STATEMENT
Title CFD simulation using fluent to determine the heat transfer coefficient of a packed bed system /
Statement of responsibility, etc. Lim Sing Wee
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Kuantan, Pahang :
Name of publisher, distributor, etc. UMP,
Date of publication, distribution, etc. 2012
300 ## - PHYSICAL DESCRIPTION
Extent xiii, 43 p. :
Other physical details ill. (some col.) ;
Dimensions 30 cm. +
Accompanying material 1 CD-ROM
502 ## - DISSERTATION NOTE
Dissertation note Project paper (Bachelor of Mechanical Engineering with Automotive Engineering) -- Universiti Malaysia Pahang - 2012
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliography : p.35-36
520 3# - SUMMARY, ETC.
Summary, etc. In this research, a packed bed is used in the heat exchanger will be considered. Particle to fluid heat transfer coefficient is a primal important when analyzing the performance of a heat exchanger. Basically, a bed packed consists of 44- spherical aluminium particles with proper arrangements is located inside a pipe wall will be considered in this research. A hot fluid is flowing through the packed bed in a solid pipe wall and from here, there will be a pressure drop though this system regarding to the fluid mechanic mechanism. Besides, temperature difference between fluid and solid will cause the convection process and from here heat transfer coefficient can be determined. After the results are taken from the numerical experiment, a comparison between the experimental results with past researcher's results can be done and together with the comparison of calculation using relevant formula.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Heat
General subdivision Transmission
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
  Not lost   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   TJ260 .L56 2012 rs Bc. 0000069713 04/09/2019 1 04/09/2019 Final Year Report
  Not lost   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   CD 6609 | TJ260 .L56 2012 rs Bc. 0000069714 04/09/2019 1 04/09/2019 Final Year Report

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us