Comparative study of the strain signal and the edited strain signal / (Record no. 3871)

MARC details
000 -LEADER
fixed length control field 02085ntm a2200229 a 4500
001 - CONTROL NUMBER
control field vtls000071967
003 - CONTROL NUMBER IDENTIFIER
control field KUKTEM
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251114204538.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 130617t2012 my da f m 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0005713(Local)
039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE]
Level of rules in bibliographic description 201905211459
Level of effort used to assign nonsubject heading access points hanafiah
-- 201306171152
-- huda
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) TA413.5 .F35 2012 rs Bc.
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Muhamad Faizal Abd Ghani
245 10 - TITLE STATEMENT
Title Comparative study of the strain signal and the edited strain signal /
Statement of responsibility, etc. Muhamad Faizal bin Abd Ghani
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Kuantan, Pahang :
Name of publisher, distributor, etc. UMP,
Date of publication, distribution, etc. 2012
300 ## - PHYSICAL DESCRIPTION
Extent xviii, 74 p. :
Other physical details ill. (some col.) ;
Dimensions 30 cm. +
Accompanying material 1 CD-ROM
502 ## - DISSERTATION NOTE
Dissertation note Project paper (Bachelor of Mechanical Engineering) -- Universiti Malaysia Pahang - 2012
520 3# - SUMMARY, ETC.
Summary, etc. This study presents the comparative study between the original strain signal and its edited strain signal. In this study, the data of fatigue strain loading on an automobile coil spring was used and the purpose to this component is because it been identified as one of the critical component in an automobile. The strain signal editing process was performed by removing low amplitude cycles were eliminated based on the cut-off level of the signal energy distribution in the time representation. Thus, the new edited signal was obtained which has retained almost 100% of the original fatigue damage and has equivalent signal statistic. The original and edited strain signals were analysed for predicting the fatigue damage of the coil spring. A comparison study of the fatigue damage and the highest damage zone obtained from the original strain signal and the edited strain signal carried out. From the result obtained, the prediction of the fatigue damage and the highest damage zone for both strain signals original and edited is equivalents. Hence, for the laboratory fatigue testing the shortened signals that was produced from damage editing process can be used as a tool to accelerate the fatigue testing.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Strains and stresses
General subdivision Measurement
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
  Not lost   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   TA413.5 .F35 2012 rs Bc. 0000069731 04/09/2019 1 04/09/2019 Final Year Report
  Not lost   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   CD 6618 | TA413.5 .F35 2012 rs Bc. 0000069732 04/09/2019 1 04/09/2019 Final Year Report

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us