Optimal design of heat recovery system / (Record no. 3904)

MARC details
000 -LEADER
fixed length control field 02018nam a2200241 a 4500
001 - CONTROL NUMBER
control field vtls000075728
003 - CONTROL NUMBER IDENTIFIER
control field KUKTEM
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251114204539.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 131025t2013 my da f abm 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0003558(Local)
039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE]
Level of rules in bibliographic description 201905152110
Level of effort used to assign nonsubject heading access points zulaiha
-- 201310251054
-- nabilah
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) TJ260 .A97 2013 rs Bc.
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Azri Marmoh
245 10 - TITLE STATEMENT
Title Optimal design of heat recovery system /
Statement of responsibility, etc. Azri Marmoh
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Kuantan, Pahang :
Name of publisher, distributor, etc. UMP,
Date of publication, distribution, etc. 2013
300 ## - PHYSICAL DESCRIPTION
Extent xv, 72 p. :
Other physical details ill. ;
Dimensions 30 cm. +
Accompanying material 1 CD-ROM
502 ## - DISSERTATION NOTE
Dissertation note Project paper (Bachelor of Chemical Engineering) -- Universiti Malaysia Pahang – 2013
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliography : p. 48-51
520 3# - SUMMARY, ETC.
Summary, etc. High energy usage has been a huge problem in all areas of the chemical industry. With the growing awareness of green engineering, energy usage needs to be reduced by some means. This study explains how energy usage is reduced through atechnique called process integration which is achieved through mathematical programming. Software called Generalized Algebraic Modeling System (GAMS) is used to do the mathematical programming. Although many methods can be used, this paper covers the usage of Linear Programming (LP) to reduce energy usage. An ethylbenzene plant in Korea was used as a case study (Yoon et al., 2007) to verify the model developed. Transportation model was used as the mathematical model to solve this problem. The procedures involved 3 steps, (1) data extraction from the process data, (2) superstructure representation, and (3) mathematical modeling. The simulation results produced by GAMS were analysed based on three important criteria to select the valid match ups between hot streams and cold streams. As a result, usage of cooling and heating utility was reduced by 79.3% and 28.2% respectively.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Heat recovery
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
  Not lost   Not for loan UMPLIB GAMBANG UMPLIB GAMBANG 04/09/2019   TJ260 .A97 2013 rs Bc. 0000074577 04/09/2019 1 04/09/2019 Final Year Report
  Not lost   Not for loan UMPLIB GAMBANG UMPLIB GAMBANG 04/09/2019   CD 6988 | TJ260 .A97 2013 rs Bc. 0000074578 04/09/2019 1 04/09/2019 Final Year Report

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us