MARC details
| 000 -LEADER |
| fixed length control field |
02131nam a2200253 a 4500 |
| 001 - CONTROL NUMBER |
| control field |
vtls000075151 |
| 003 - CONTROL NUMBER IDENTIFIER |
| control field |
KUKTEM |
| 005 - DATE AND TIME OF LATEST TRANSACTION |
| control field |
20251114204540.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
| fixed length control field |
131008t2012 my a f m 000 0 eng d |
| 020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
| International Standard Book Number |
THE0006938(Local) |
| 039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE] |
| Level of rules in bibliographic description |
201906131136 |
| Level of effort used to assign nonsubject heading access points |
aida |
| -- |
201310081025 |
| -- |
Fida |
| 040 ## - CATALOGING SOURCE |
| Original cataloging agency |
UMP |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) |
TK7872.D48 F37 2012 rs Bc. |
| 100 0# - MAIN ENTRY--PERSONAL NAME |
| Personal name |
Nurul Farah Ain Abdul Hamid |
| 245 10 - TITLE STATEMENT |
| Title |
Warning system for ethic of visitor in hospital ICU using vision system / |
| Statement of responsibility, etc. |
Nurul Farah Ain Abdul Hamid |
| 260 ## - PUBLICATION, DISTRIBUTION, ETC. |
| Place of publication, distribution, etc. |
Kuantan, Pahang : |
| Name of publisher, distributor, etc. |
UMP, |
| Date of publication, distribution, etc. |
2012 |
| 300 ## - PHYSICAL DESCRIPTION |
| Extent |
vii, 47 p. : |
| Other physical details |
ill. (some col.) ; |
| Dimensions |
30 cm. + |
| Accompanying material |
1 CD-ROM |
| 502 ## - DISSERTATION NOTE |
| Dissertation note |
Project paper (Bachelor of Electrical Engineering (Electronics)) -- Universiti Malaysia Pahang - 2012 |
| 504 ## - BIBLIOGRAPHY, ETC. NOTE |
| Bibliography, etc. note |
Bibliography : p. 46-47 |
| 520 3# - SUMMARY, ETC. |
| Summary, etc. |
A warning system using vision system for ethic of visitor in hospital ICU (Intensive Care Unit) is developed. This system will enable the ICU’s guard monitors the movement of visitor who entered patient’s room at ICU without followed the correct order path. The order path that have been set where: area 1 was a door which the first area this system will detects the moving object, area 2 represented sink area and lastly area 3 represented the patient’s room. To overcome this problem, currently this system will be trained to detect and track moving object in the observation scenes using static camera. This is done with the camera as a vision sensor and area of ICU room will be display. Then, it will sent data to the computer for the image processing process. Based on video processing using MATLAB software and apllications, it consists of four main stages, namely: moving object detection and tracking, analysis of sum of pixels on the set area, interfacing with GUI (Graphical User Interface) and warning system activation. This system will notifies the ICU’s guard in making sure that the visitor will follow the correct path before entering the patient’s room. |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Detectors |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Computer vision |