MARC details
| 000 -LEADER |
| fixed length control field |
02282ntm a2200253 a 4500 |
| 001 - CONTROL NUMBER |
| control field |
vtls000074004 |
| 003 - CONTROL NUMBER IDENTIFIER |
| control field |
KUKTEM |
| 005 - DATE AND TIME OF LATEST TRANSACTION |
| control field |
20251114204540.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
| fixed length control field |
130822t2013 my da f m 000 0 eng d |
| 020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
| International Standard Book Number |
THE0004721(Local) |
| 039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE] |
| Level of rules in bibliographic description |
201905141026 |
| Level of effort used to assign nonsubject heading access points |
smfh |
| Level of effort used to assign subject headings |
201308221558 |
| Level of effort used to assign classification |
huda |
| -- |
201308221558 |
| -- |
huda |
| 040 ## - CATALOGING SOURCE |
| Original cataloging agency |
UMP |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) |
TP363 .K36 2013 rs Bc. |
| 100 0# - MAIN ENTRY--PERSONAL NAME |
| Personal name |
Muhammad Kamal Jamali |
| 245 10 - TITLE STATEMENT |
| Title |
Study the effect of oxygen to methane ratio on the temperature of partial oxidation unit at direct reduction plant by using CFD / |
| Statement of responsibility, etc. |
Muhammad Kamal Jamali |
| 260 ## - PUBLICATION, DISTRIBUTION, ETC. |
| Place of publication, distribution, etc. |
Kuantan, Pahang : |
| Name of publisher, distributor, etc. |
UMP, |
| Date of publication, distribution, etc. |
2013 |
| 300 ## - PHYSICAL DESCRIPTION |
| Extent |
xiii, 46 p. : |
| Other physical details |
ill. (some col.) ; |
| Dimensions |
30 cm. + |
| Accompanying material |
1 CD-ROM |
| 502 ## - DISSERTATION NOTE |
| Dissertation note |
Project paper (Bachelor of Chemical Engineering (Gas Technology)) -- Universiti Malaysia Pahang - 2013 |
| 504 ## - BIBLIOGRAPHY, ETC. NOTE |
| Bibliography, etc. note |
Bibliogrpahy : p. 44-46 |
| 520 3# - SUMMARY, ETC. |
| Summary, etc. |
Direct Reduction Plant is a plant that can produce high quality of iron product. In this plant, the very important thing is the Partial Oxidation (PO) system that allows increasing the productive rate, the quality of Direct Reduced Iron (DRI), and can save the usage of natural gas consumption. Besides, there is a transfer line with two oxygen lances is situated between the gas heater and reactor. The main objective of this study is to consider the oxygen to methane ratio supplied form the oxygen lance on the temperature profile in the combustion chamber. High temperature in the transfer line is needed in order to get high quality of iron product. In order to get the result, the simulation was performed by using Computational Fluid Dynamic (CFD) software that contents Fluent and Gambit. Volume meshing in GAMBIT is very important part before doing simulation in FLUENT as a solver. For further modification, only one lance of oxygen is considered in this study. Besides, the steady state condition of the partial oxidation system also included in this report. From this study, the temperature profile of Partial Oxidation system can be determined thus can give better performance for this system. |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Heat |
| General subdivision |
Transmission |
| -- |
Computer simulation |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Heat exchangers |
| General subdivision |
Fluid dynamics |
| -- |
Computer simulation |