Simulation of center location of fluid flow in shear driven cavity using lattice Boltzmann method / (Record no. 4010)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 01671nam a2200241 a 4500 |
| 001 - CONTROL NUMBER | |
| control field | vtls000075771 |
| 003 - CONTROL NUMBER IDENTIFIER | |
| control field | KUKTEM |
| 005 - DATE AND TIME OF LATEST TRANSACTION | |
| control field | 20251114204543.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
| fixed length control field | 131029t2012 my da f abm 000 0 eng d |
| 020 ## - INTERNATIONAL STANDARD BOOK NUMBER | |
| International Standard Book Number | THE0005648(Local) |
| 039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE] | |
| Level of rules in bibliographic description | 201905171503 |
| Level of effort used to assign nonsubject heading access points | hanafiah |
| -- | 201310291016 |
| -- | nabilah |
| 040 ## - CATALOGING SOURCE | |
| Original cataloging agency | UMP |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) | |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) | TA357 .H36 2012 rs Bc. |
| 100 0# - MAIN ENTRY--PERSONAL NAME | |
| Personal name | Wan Mohd Hanif Othman |
| 245 10 - TITLE STATEMENT | |
| Title | Simulation of center location of fluid flow in shear driven cavity using lattice Boltzmann method / |
| Statement of responsibility, etc. | Wan Mohd Hanif Othman |
| 260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
| Place of publication, distribution, etc. | Kuantan, Pahang : |
| Name of publisher, distributor, etc. | UMP, |
| Date of publication, distribution, etc. | 2012 |
| 300 ## - PHYSICAL DESCRIPTION | |
| Extent | xii, 42 p. : |
| Other physical details | ill. ; |
| Dimensions | 30 cm. + |
| Accompanying material | 1 CD-ROM |
| 502 ## - DISSERTATION NOTE | |
| Dissertation note | Project paper (Bachelor of Mechanical Engineering) -- Universiti Malaysia Pahang – 2012 |
| 504 ## - BIBLIOGRAPHY, ETC. NOTE | |
| Bibliography, etc. note | Bibliography : p. 41-42 |
| 520 3# - SUMMARY, ETC. | |
| Summary, etc. | The study of center location of lid driven cavity using lattice Boltzmann method is all about the of the fluid dynamic base on the simulation and prediction the flow. The study is base on steady flow and transient flow using Lattice Boltzmann method to understant the capability of Lattice Boltzmann. The simulation of Lattice Boltzmann is using FOTRAN software. The result is compare with Ghia et al to validate the stream function is in good arrangement and also can determine the capability of LBM. The result have been compare with simulation lid driven cavity using ANSYS(FLUENT) using navier stoke solver at the transient flow in Reynolds number 100 to 10000. From the simulation, the lattice Boltzmann method is capable at Reynolds number below than 7500. |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | Fluid dynamics |
| Withdrawn status | Lost status | Damaged status | Not for loan | Home library | Current library | Date acquired | Total checkouts | Full call number | Barcode | Date last seen | Copy number | Price effective from | Koha item type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Not lost | Not for loan | UMPLIB PEKAN | UMPLIB PEKAN | 04/09/2019 | TA357 .H36 2012 rs Bc. | 0000076113 | 04/09/2019 | 1 | 04/09/2019 | Final Year Report | |||
| Not lost | Not for loan | UMPLIB PEKAN | UMPLIB PEKAN | 04/09/2019 | CD 7318 | TA357 .H36 2012 rs Bc. | 0000076114 | 04/09/2019 | 1 | 04/09/2019 | Final Year Report |