Copper removal from aqueous solution using Amberlite IR-120 cation exchanger mixed matrix membrane chromatography / (Record no. 4213)

MARC details
000 -LEADER
fixed length control field 01796nam a2200253 a 4500
001 - CONTROL NUMBER
control field vtls000075941
003 - CONTROL NUMBER IDENTIFIER
control field KUKTEM
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251114204550.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 131112t2013 my da f m 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0002779(Local)
039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE]
Level of rules in bibliographic description 201905280937
Level of effort used to assign nonsubject heading access points nazirah
Level of effort used to assign subject headings 201311141128
Level of effort used to assign classification nabilah
-- 201311120929
-- nabilah
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) TA480.C7 Z87 2013 rs Bc.
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Zuraidah Mohamad
245 10 - TITLE STATEMENT
Title Copper removal from aqueous solution using Amberlite IR-120 cation exchanger mixed matrix membrane chromatography /
Statement of responsibility, etc. Zuraidah Mohamad
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Kuantan, Pahang :
Name of publisher, distributor, etc. UMP,
Date of publication, distribution, etc. 2013
300 ## - PHYSICAL DESCRIPTION
Extent xiv, 56 p. :
Other physical details ill. ;
Dimensions 30 cm. +
Accompanying material 1 CD-ROM
502 ## - DISSERTATION NOTE
Dissertation note Project paper (Bachelor of Chemical Engineering) -- Universiti Malaysia Pahang – 2013
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliography : p. 40-45
520 3# - SUMMARY, ETC.
Summary, etc. Copper is one of the toxic heavy metals that contaminated in industrial wastewater. Cation exchange chromatography is widely used for the removal of copper (II)from the water. In this study, Amberlite IR-120 cation exchanger resin was used to prepare mixed matrix membrane (MMM) chromatography by blending the resin in ethylene vinyl alcohol (EVAL) base polymer solution. The EVAL composition was varied in the range of 15to 20 wt% with fixed Amberlite IR-120 loading at 30%. The adsorption isotherm of cation MMM was determined from batch binding experiment. From the result, it shows that MM15, prepared at 15 wt% EVAL gave high amount of copper binding of 5688.190 mg Cu/g adsorbent.In regeneration experiments using 0.1M HCl, more effective regeneration was showed byMMM20, prepared at 20 wt% EVAL, than EVAL membrane.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Copper
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Chromatographic analysis
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
  Not lost   Not for loan UMPLIB GAMBANG UMPLIB GAMBANG 04/09/2019   TA480.C7 Z87 2013 rs Bc. 0000074651 04/09/2019 1 04/09/2019 Final Year Report
  Not lost   Not for loan UMPLIB GAMBANG UMPLIB GAMBANG 04/09/2019   CD 7025 | TA480.C7 Z87 2013 rs Bc. 0000074652 04/09/2019 1 04/09/2019 Final Year Report

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us