MARC details
| 000 -LEADER |
| fixed length control field |
01796nam a2200253 a 4500 |
| 001 - CONTROL NUMBER |
| control field |
vtls000075941 |
| 003 - CONTROL NUMBER IDENTIFIER |
| control field |
KUKTEM |
| 005 - DATE AND TIME OF LATEST TRANSACTION |
| control field |
20251114204550.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
| fixed length control field |
131112t2013 my da f m 000 0 eng d |
| 020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
| International Standard Book Number |
THE0002779(Local) |
| 039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE] |
| Level of rules in bibliographic description |
201905280937 |
| Level of effort used to assign nonsubject heading access points |
nazirah |
| Level of effort used to assign subject headings |
201311141128 |
| Level of effort used to assign classification |
nabilah |
| -- |
201311120929 |
| -- |
nabilah |
| 040 ## - CATALOGING SOURCE |
| Original cataloging agency |
UMP |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) |
TA480.C7 Z87 2013 rs Bc. |
| 100 0# - MAIN ENTRY--PERSONAL NAME |
| Personal name |
Zuraidah Mohamad |
| 245 10 - TITLE STATEMENT |
| Title |
Copper removal from aqueous solution using Amberlite IR-120 cation exchanger mixed matrix membrane chromatography / |
| Statement of responsibility, etc. |
Zuraidah Mohamad |
| 260 ## - PUBLICATION, DISTRIBUTION, ETC. |
| Place of publication, distribution, etc. |
Kuantan, Pahang : |
| Name of publisher, distributor, etc. |
UMP, |
| Date of publication, distribution, etc. |
2013 |
| 300 ## - PHYSICAL DESCRIPTION |
| Extent |
xiv, 56 p. : |
| Other physical details |
ill. ; |
| Dimensions |
30 cm. + |
| Accompanying material |
1 CD-ROM |
| 502 ## - DISSERTATION NOTE |
| Dissertation note |
Project paper (Bachelor of Chemical Engineering) -- Universiti Malaysia Pahang – 2013 |
| 504 ## - BIBLIOGRAPHY, ETC. NOTE |
| Bibliography, etc. note |
Bibliography : p. 40-45 |
| 520 3# - SUMMARY, ETC. |
| Summary, etc. |
Copper is one of the toxic heavy metals that contaminated in industrial wastewater. Cation exchange chromatography is widely used for the removal of copper (II)from the water. In this study, Amberlite IR-120 cation exchanger resin was used to prepare mixed matrix membrane (MMM) chromatography by blending the resin in ethylene vinyl alcohol (EVAL) base polymer solution. The EVAL composition was varied in the range of 15to 20 wt% with fixed Amberlite IR-120 loading at 30%. The adsorption isotherm of cation MMM was determined from batch binding experiment. From the result, it shows that MM15, prepared at 15 wt% EVAL gave high amount of copper binding of 5688.190 mg Cu/g adsorbent.In regeneration experiments using 0.1M HCl, more effective regeneration was showed byMMM20, prepared at 20 wt% EVAL, than EVAL membrane. |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Copper |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Chromatographic analysis |