MARC details
| 000 -LEADER |
| fixed length control field |
02667nam a2200277 4500 |
| 001 - CONTROL NUMBER |
| control field |
vtls000077933 |
| 003 - CONTROL NUMBER IDENTIFIER |
| control field |
KUKTEM |
| 005 - DATE AND TIME OF LATEST TRANSACTION |
| control field |
20251114204602.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
| fixed length control field |
140506 00 eng |
| 020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
| International Standard Book Number |
THE0005535(Local) |
| 039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE] |
| Level of rules in bibliographic description |
201905161058 |
| Level of effort used to assign nonsubject heading access points |
hanafiah |
| Level of effort used to assign subject headings |
201905021553 |
| Level of effort used to assign classification |
amy2 |
| Level of effort used to assign subject headings |
201905021552 |
| Level of effort used to assign classification |
amy2 |
| -- |
201405061125 |
| -- |
training3 |
| 040 ## - CATALOGING SOURCE |
| Original cataloging agency |
UMP |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) |
RD598.35.M42 .I85 2012 rs Bc. |
| 100 0# - MAIN ENTRY--PERSONAL NAME |
| Personal name |
Mohammad Iskandar Othman |
| 245 10 - TITLE STATEMENT |
| Title |
Analysis of blood flow in 3d heart valve model under steady state condition / |
| Statement of responsibility, etc. |
Mohammad Iskandar Othman |
| 260 ## - PUBLICATION, DISTRIBUTION, ETC. |
| Place of publication, distribution, etc. |
Kuantan, Pahang : |
| Name of publisher, distributor, etc. |
UMP, |
| Date of publication, distribution, etc. |
2012 |
| 300 ## - PHYSICAL DESCRIPTION |
| Extent |
xviii, 84 p. : |
| Other physical details |
ill. (some col.) ; |
| Dimensions |
30 cm. + |
| Accompanying material |
1 CD-ROM |
| 502 ## - DISSERTATION NOTE |
| Dissertation note |
Project paper (Bachelor of Mechanical Engineering) -- Universiti Malaysia Pahang – 2012 |
| 504 ## - BIBLIOGRAPHY, ETC. NOTE |
| Bibliography, etc. note |
Bibliography : p. 83-84 |
| 520 3# - SUMMARY, ETC. |
| Summary, etc. |
Mitral valve (MV) and Aortic valve (AV) is very important in circulatory blood inside the heart which function as a gate for the blood flow. Since the heart valves not working properly, the normal flow of blood inside the heart will be interrupeted. Malfunctioning Mitral Valve and Aortic Valve will cause death if it not immediately detected. The aims of this study are to investigate the blood flow pattern for MV and AV in 3D view which developed by ADINA-FSI application. All the parameter of blood obtained from the previous studies. Both of valve models have been implemented without ventricles and presented as a Newtonian fluid flow in steady condition. The simulation from this study will cover the blood flow pattern in term of velocity, effective stress on the leaflets, strain occurred in the critical area of both heart valves and the nodal pressure pattern flow during the systolic process phase. Moreover, these studies enable to investigate performance characteristics such as effective stress and strain which are very difficult to evaluate experimentally. The findings showed, the velocity and nodal pressure are linear correlation with the blood pressure increased during systole process. Effective stress and strain results showed the critical area region and maximum values with fix Young Modulus 2MPa. The significant simulation results from this study were very useful to give a clear view to the medical practitioners about the pattern of blood flow through MV and AV. Furthermore, these models can be used to investigate heart valve failure and subsequent surgical repair treatment. |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Heart valve |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Mitral valve |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Aortic valve |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Heart,mechanical |