Analysis of blood flow in 3d heart valve model under steady state condition / (Record no. 4583)

MARC details
000 -LEADER
fixed length control field 02667nam a2200277 4500
001 - CONTROL NUMBER
control field vtls000077933
003 - CONTROL NUMBER IDENTIFIER
control field KUKTEM
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251114204602.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 140506 00 eng
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0005535(Local)
039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE]
Level of rules in bibliographic description 201905161058
Level of effort used to assign nonsubject heading access points hanafiah
Level of effort used to assign subject headings 201905021553
Level of effort used to assign classification amy2
Level of effort used to assign subject headings 201905021552
Level of effort used to assign classification amy2
-- 201405061125
-- training3
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) RD598.35.M42 .I85 2012 rs Bc.
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Mohammad Iskandar Othman
245 10 - TITLE STATEMENT
Title Analysis of blood flow in 3d heart valve model under steady state condition /
Statement of responsibility, etc. Mohammad Iskandar Othman
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Kuantan, Pahang :
Name of publisher, distributor, etc. UMP,
Date of publication, distribution, etc. 2012
300 ## - PHYSICAL DESCRIPTION
Extent xviii, 84 p. :
Other physical details ill. (some col.) ;
Dimensions 30 cm. +
Accompanying material 1 CD-ROM
502 ## - DISSERTATION NOTE
Dissertation note Project paper (Bachelor of Mechanical Engineering) -- Universiti Malaysia Pahang – 2012
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliography : p. 83-84
520 3# - SUMMARY, ETC.
Summary, etc. Mitral valve (MV) and Aortic valve (AV) is very important in circulatory blood inside the heart which function as a gate for the blood flow. Since the heart valves not working properly, the normal flow of blood inside the heart will be interrupeted. Malfunctioning Mitral Valve and Aortic Valve will cause death if it not immediately detected. The aims of this study are to investigate the blood flow pattern for MV and AV in 3D view which developed by ADINA-FSI application. All the parameter of blood obtained from the previous studies. Both of valve models have been implemented without ventricles and presented as a Newtonian fluid flow in steady condition. The simulation from this study will cover the blood flow pattern in term of velocity, effective stress on the leaflets, strain occurred in the critical area of both heart valves and the nodal pressure pattern flow during the systolic process phase. Moreover, these studies enable to investigate performance characteristics such as effective stress and strain which are very difficult to evaluate experimentally. The findings showed, the velocity and nodal pressure are linear correlation with the blood pressure increased during systole process. Effective stress and strain results showed the critical area region and maximum values with fix Young Modulus 2MPa. The significant simulation results from this study were very useful to give a clear view to the medical practitioners about the pattern of blood flow through MV and AV. Furthermore, these models can be used to investigate heart valve failure and subsequent surgical repair treatment.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Heart valve
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Mitral valve
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Aortic valve
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Heart,mechanical
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
  Not lost   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   RD598.35.M42 .I85 2012 rs Bc. 0000072709 04/09/2019 1 04/09/2019 Final Year Report
  Not lost   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   CD 6882 | RD598.35.M42 .I85 2012 rs Bc. 0000072710 04/09/2019 1 04/09/2019 Final Year Report

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us