Measurement and numerical simulation of internal air flow in faculty of mechanical engineering admin office ventilation system / (Record no. 4661)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 01996nam a2200241 a 4500 |
| 001 - CONTROL NUMBER | |
| control field | vtls000077634 |
| 003 - CONTROL NUMBER IDENTIFIER | |
| control field | KUKTEM |
| 005 - DATE AND TIME OF LATEST TRANSACTION | |
| control field | 20251114204605.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
| fixed length control field | 140416t2012 my da f m 000 0 eng d |
| 020 ## - INTERNATIONAL STANDARD BOOK NUMBER | |
| International Standard Book Number | THE0006463(Local) |
| 039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE] | |
| Level of rules in bibliographic description | 201905141150 |
| Level of effort used to assign nonsubject heading access points | amirul |
| -- | 201404161202 |
| -- | Fida |
| 040 ## - CATALOGING SOURCE | |
| Original cataloging agency | UMP |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) | |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) | TJ1025 .A45 2012 rs Bc. |
| 100 0# - MAIN ENTRY--PERSONAL NAME | |
| Personal name | Mohd Amirul Husaini Saat |
| 245 10 - TITLE STATEMENT | |
| Title | Measurement and numerical simulation of internal air flow in faculty of mechanical engineering admin office ventilation system / |
| 260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
| Place of publication, distribution, etc. | Kuantan, Pahang : |
| Name of publisher, distributor, etc. | UMP, |
| Date of publication, distribution, etc. | 2012 |
| 300 ## - PHYSICAL DESCRIPTION | |
| Extent | xi, 33 p. : |
| Other physical details | ill. ; |
| Dimensions | 30 cm. + |
| Accompanying material | 1 CD-ROM |
| 502 ## - DISSERTATION NOTE | |
| Dissertation note | Project paper (Bachelor of Automotive Engineering) -- Universiti Malaysia Pahang – 2012 |
| 504 ## - BIBLIOGRAPHY, ETC. NOTE | |
| Bibliography, etc. note | Bibliography : p. 34 |
| 520 3# - SUMMARY, ETC. | |
| Summary, etc. | Ventilation unit is critical for closed room such in Faculty of Mechanical administration office to recirculate air to entire room and maintain the surrounding temperature. Air is cycled to the inlet office space from inlet diffuser and outlet vent. However, the geometry position of the inlet diffuser and the furniture in the office effect the flow of the air cannot be supply directly to occupants. For this study, the objective is to investigate and observe the flow pattern in the office area due to obstruction by some partitions. A commercial CFD software was used which is ANSYS-Fluent to run the simulation. The real office dimension is 40 meters in length, 19 meters wide and 3 meters height. For the simulation RNG kε is used as the mathematical model for the flow in CFD. Results show that the obstruction occurred and effect the air distribution which is in agreement to previous researches. Analysis has been done after the simulation and the results show that the partitions in the office in good position which is the occupants are still in comfort while in working condition. |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | Gas flow |
| Withdrawn status | Lost status | Damaged status | Not for loan | Home library | Current library | Date acquired | Total checkouts | Full call number | Barcode | Date last seen | Copy number | Price effective from | Koha item type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Not lost | Not for loan | UMPLIB PEKAN | UMPLIB PEKAN | 04/09/2019 | TJ1025 .A45 2012 rs Bc. | 0000072729 | 04/09/2019 | 1 | 04/09/2019 | Final Year Report | |||
| Not lost | Not for loan | UMPLIB PEKAN | UMPLIB PEKAN | 04/09/2019 | CD 6892 | TJ1025 .A45 2012 rs Bc. | 0000072730 | 04/09/2019 | 1 | 04/09/2019 | Final Year Report |