Sistem brek elektromagnetik boleh kawal menggunakan arus pusar / (Record no. 4770)

MARC details
000 -LEADER
fixed length control field 03406nam a2200265 a 4500
001 - CONTROL NUMBER
control field vtls000076429
003 - CONTROL NUMBER IDENTIFIER
control field KUKTEM
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251114204608.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 131220t2013 my da f m 000 0 may d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0006012(Local)
039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE]
Level of rules in bibliographic description 201905151122
Level of effort used to assign nonsubject heading access points aida
Level of effort used to assign subject headings 201710091621
Level of effort used to assign classification aishah
Level of effort used to assign subject headings 201312201542
Level of effort used to assign classification nabilah
-- 201312201431
-- nabilah
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) TF949.B7 Z35 2013 rs Thesis
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Mohamad Zairi Baharom
245 10 - TITLE STATEMENT
Title Sistem brek elektromagnetik boleh kawal menggunakan arus pusar /
Statement of responsibility, etc. Mohamad Zairi Baharom
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Bangi, Selangor :
Name of publisher, distributor, etc. Universiti Kebangsaan Malaysia,
Date of publication, distribution, etc. 2013
300 ## - PHYSICAL DESCRIPTION
Extent xv, 112 p. :
Other physical details ill. ;
Dimensions 30 cm. +
Accompanying material 1 CD-ROM
502 ## - DISSERTATION NOTE
Dissertation note Thesis (Master of Science) -- Universiti Kebangsaan Malaysia - 2013
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliography : p. [97]-101
520 3# - SUMMARY, ETC.
Summary, etc. This research presents a laboratory based experimental study of a controllable electromagnetic braking system utilising eddy current. The main focus was to study parameters related to the eddy current electromagnetic braking system and to apply the system on a test study application. This study explored potential benefits over conventional braking systems, including in the reduction of brake pad wear and wear debris contamination due to hazardous materials such as copper. The objective was to design and fabricate a test rig in order to investigate the relationship between variable parameters that affect the electromagnetic braking system response and to implement the controllable system on an undertaken test case. Two test rigs were constructed for the study on the interactions of variable parameters and on the test case application. Laboratory experiments were carried out to examine the correlation between parameters such as the coil current, air gap widths, types of disc brakes, disc thickness, and number of turns of the electromagnetic coil. Two different materials, Al6061 and Al7075 were also compared in this response experiment. In the validation part of the experiment, related optimum parameters found from the response part were used in implementing the eddy current electromagnetic braking system on a stationary exercise bicycle. From the experimental results, it was found that the parameters have some effect on certain braking behaviour. Braking force increased as the coil current increased, as also with the use of a smaller air gap, larger number of coil turns and thicker disc. Three types of disc material were tested: aluminium, zinc and copper; subsequently, aluminium was found to be the best among the three. It was also found that Al6061 performed better than Al7075. The eddy current electromagnetic brake was tested for exercise purposes, taking the coil current as the controllable parameter. Increasing the coil current caused the cycling resistance to increase, and hence the intensity of the exercise also increased. From this research, it was shown that the eddy current electromagnetic brake could be successfully implemented as a controllable braking system on a test static exercise bicycle. Thus, this system has great potential to be explored as an alternative to present-day conventional braking systems
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Magnetic brakes
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Eddy currents (Electric)
856 40 - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://ecollib.ump.edu.my/3768/">http://ecollib.ump.edu.my/3768/</a>
Public note Library access only
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
  Not lost Library of Congress Classification   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   TF949.B7 Z35 2013 rs Thesis 0000077663 04/09/2019 1 04/09/2019 Thesis
  Not lost Library of Congress Classification   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   CD 7542 | TF949.B7 Z35 2013 rs Thesis 0000077664 04/09/2019 1 04/09/2019 Thesis

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us