Heat exchanger for solar collector / (Record no. 4942)

MARC details
000 -LEADER
fixed length control field 01969ntm a2200241 a 4500
001 - CONTROL NUMBER
control field vtls000079805
003 - CONTROL NUMBER IDENTIFIER
control field KUKTEM
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251114204614.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 140605t2013 my a f m 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0006254(Local)
039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE]
Level of rules in bibliographic description 201905161432
Level of effort used to assign nonsubject heading access points aida
Level of effort used to assign subject headings 201406061102
Level of effort used to assign classification training2
Level of effort used to assign subject headings 201406060929
Level of effort used to assign classification Fida
Level of effort used to assign subject headings 201406051054
Level of effort used to assign classification training2
-- 201406050856
-- training2
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) TJ263 .L34 2013 rs Bc.
100 1# - MAIN ENTRY--PERSONAL NAME
Personal name Lagunesvary Ganesan
245 10 - TITLE STATEMENT
Title Heat exchanger for solar collector /
Statement of responsibility, etc. Lagunesvary Ganesan
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Kuantan, Pahang :
Name of publisher, distributor, etc. UMP,
Date of publication, distribution, etc. 2013
300 ## - PHYSICAL DESCRIPTION
Extent xvii, 91 p. :
Other physical details ill. (some col.) ;
Dimensions 30 cm. +
Accompanying material 1 CD-ROM
502 ## - DISSERTATION NOTE
Dissertation note Project paper (Bachelor of Mechanical Engineering) -- Universiti Malaysia Pahang - 2013
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliography : p. 67-69
520 3# - SUMMARY, ETC.
Summary, etc. The objective of this study is to design and simulate an optimum heat exchanger for evacuated tube solar collector. The simulation was carried out in ANSYS FLUENT 14.0 with two different tube designs, spring and S-Shape. Four materials was analysed in this study, copper, aluminium, steel and brass. Both tube designs are varied by three different sizes and four shapes, circular, ellipse, square and hexagon. There are four flow rates are considered in the study, 1kg/s, 0.5kg/s, 0.25kg/s and 0.01kg/s. Based on the study, copper 61.25% effective compare to aluminium and followed by steel and brass. In the overall, spring design performs better than S-Shape design and ellipse shape tube in leading. At the flow rate of 1kg/s, large size ellipse-spring tube design provide higher performance with rate of heat transfer 109192.02W. At flow rate of 0.5kg/s and 0.25kg/s medium size ellipse-spring tube design performs better than the others. While at the flow rate of 0.01kg/s, small size ellipse-S-Shape design is chosen.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Heat exchangers
General subdivision Design and construction
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
  Not lost   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   TJ263 .L34 2013 rs Bc. 0000086202 04/09/2019 1 04/09/2019 Final Year Report
  Not lost   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   CD 8042 | TJ263 .L34 2013 rs Bc. 0000086203 04/09/2019 1 04/09/2019 Final Year Report

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us