MARC details
| 000 -LEADER |
| fixed length control field |
02242ntm a2200253 a 4500 |
| 001 - CONTROL NUMBER |
| control field |
vtls000081876 |
| 003 - CONTROL NUMBER IDENTIFIER |
| control field |
KUKTEM |
| 005 - DATE AND TIME OF LATEST TRANSACTION |
| control field |
20251117113226.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
| fixed length control field |
141008t2013 my da f m 000 0 eng d |
| 020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
| International Standard Book Number |
THE0006397(Local) |
| 039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE] |
| Level of rules in bibliographic description |
201905131444 |
| Level of effort used to assign nonsubject heading access points |
amirul |
| Level of effort used to assign subject headings |
201411051143 |
| Level of effort used to assign classification |
safura |
| -- |
201410080956 |
| -- |
Fida |
| 040 ## - CATALOGING SOURCE |
| Original cataloging agency |
UMP |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) |
TJ808.6 .S29 2013 r Bc. |
| 100 0# - MAIN ENTRY--PERSONAL NAME |
| Personal name |
Sazwan Sahar |
| 245 10 - TITLE STATEMENT |
| Title |
Design and analysis of the test section for an open channel flow flume / |
| Statement of responsibility, etc. |
Sazwan Sahar |
| 260 ## - PUBLICATION, DISTRIBUTION, ETC. |
| Place of publication, distribution, etc. |
Kuantan, Pahang : |
| Name of publisher, distributor, etc. |
UMP, |
| Date of publication, distribution, etc. |
2013 |
| 300 ## - PHYSICAL DESCRIPTION |
| Extent |
xv, 79 p. : |
| Other physical details |
ill. (some col.) ; |
| Dimensions |
30 cm. + |
| Accompanying material |
1 CD-ROM |
| 502 ## - DISSERTATION NOTE |
| Dissertation note |
Project paper (Bachelor of Mechanical Engineering) -- Universiti Malaysia Pahang - 2013 |
| 504 ## - BIBLIOGRAPHY, ETC. NOTE |
| Bibliography, etc. note |
Bibliography : p.61-63 |
| 520 3# - SUMMARY, ETC. |
| Summary, etc. |
The needs of renewable energy is now in urgency as the source of the fossil energy is depleting from day to day. This study will focus on the potential energy extraction from the river flow to generate electricity and aiming is to design and analyze the test section for an open channel flume. The objective of the study is to design and analyze the test section for an open channel flume. Five concept designs for a flume were constructed and Flow Simulation Package was used to simulate the flow condition in the developed models. Result indicated that there is a significant difference across the test section between all the five designs in terms of pressure drop, velocity, turbulence intensity, as well as the velocity profile pattern. Based on the investigation, the best result derived from Design 5 which has been resulted in the average velocity of 3.36 m/s in the test section, average total pressure of 1172.5 kPa with the pressure drop of 6.56 kPa, and average turbulence intensity of 21.15%. Velocity profile gave a normal pattern and in agreement with the principal of zero-slip condition. These finding led to the conclusion that Design 5 configuration gave the best quality of flow condition and properties in the test section compared to the other four designs based on the analysis result. |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Renewable energy sources |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Flumes |