Separation of aromatic from aliphatic by using [EIM][ETSO4] ionic liquid / (Record no. 5237)

MARC details
000 -LEADER
fixed length control field 02110ntm a2200241 a 4500
001 - CONTROL NUMBER
control field vtls000083355
003 - CONTROL NUMBER IDENTIFIER
control field KUKTEM
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251117113234.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 141112t2013 my a f m 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0002138(Local)
039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE]
Level of rules in bibliographic description 201905131656
Level of effort used to assign nonsubject heading access points yusri
Level of effort used to assign subject headings 201411131506
Level of effort used to assign classification ariffin
Level of effort used to assign subject headings 201411121511
Level of effort used to assign classification ariffin
-- 201411121511
-- ariffin
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) QD331 .A75 2013 r Bc.
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Che Ahmad Arif Che Mud
245 10 - TITLE STATEMENT
Title Separation of aromatic from aliphatic by using [EIM][ETSO4] ionic liquid /
Statement of responsibility, etc. Che Ahmad Arif Che Mud
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Kuantan, Pahang :
Name of publisher, distributor, etc. UMP,
Date of publication, distribution, etc. 2013
300 ## - PHYSICAL DESCRIPTION
Extent xv, 59 p. :
Other physical details ill. (some col.) ;
Dimensions 30 cm. +
Accompanying material 1 CD-ROM
502 ## - DISSERTATION NOTE
Dissertation note Project paper (Bachelor of Chemical Engineering (Gas Technology) -- Universiti Malaysia Pahang – 2013
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliography : p. 56-57
520 3# - SUMMARY, ETC.
Summary, etc. The separation of aromatic from the aliphatic hydrocarbon mixtures are very challenging since these hydrocarbons have boiling point in a close range and several combination form an azeotrope. Toluene and n-heptane are known to have a very close boiling point, thus difficult to separate by fractionation with distillation. The present studies focusing on separating toluene from n-heptane using 3-ethylimidazolium-ethylsulfate [EIM][EtSO4]. From the analysis of data by using the FTIR and HPLC, the functional group of ionic liquid can be determined as amine group and for the analyzing the data for the extraction, the removal of the toluene from the mixture shows the positive results where the toluene was separated from the aromatic/aliphatic mixtures increases and it depends on the amount or percentages of the volume ratios of the toluene compound in the mixtures. From the results of stirring, it shows that the distribution coefficient of toluene was decreasing with the increasing of the removal of the toluene from the toluene/n-heptane and the selectivities at the temperature 30°C was increasing with decreasing toluene content in the feed.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Aromatic compounds
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
  Not lost   Not for loan UMPLIB GAMBANG UMPLIB GAMBANG 04/09/2019   QD331 .A75 2013 r Bc. 0000087089 04/09/2019 1 04/09/2019 Final Year Report
  Not lost   Not for loan UMPLIB GAMBANG UMPLIB GAMBANG 04/09/2019   CD 8329 | QD331 .A75 2013 r Bc. 0000087090 04/09/2019 1 04/09/2019 Final Year Report

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us