Design and analysis of piping system for an open channel flume’s flow / (Record no. 5541)

MARC details
000 -LEADER
fixed length control field 02940ntm a2200253 a 4500
001 - CONTROL NUMBER
control field vtls000083928
003 - CONTROL NUMBER IDENTIFIER
control field KUKTEM
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251117113243.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 141121t2013 my a f m 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0006394(Local)
039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE]
Level of rules in bibliographic description 201905131441
Level of effort used to assign nonsubject heading access points amirul
Level of effort used to assign subject headings 201411211010
Level of effort used to assign classification ariffin
-- 201411210906
-- ariffin
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) TJ808.6 .H36 2013 r Bc.
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Hamdi Abdullah Mohammed Mudhsh
245 10 - TITLE STATEMENT
Title Design and analysis of piping system for an open channel flume’s flow /
Statement of responsibility, etc. Hamdi Abdullah Mohammed Mudhsh
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Kuantan, Pahang :
Name of publisher, distributor, etc. UMP ,
Date of publication, distribution, etc. 2013
300 ## - PHYSICAL DESCRIPTION
Extent xiv, 60 p. :
Other physical details ill. (some col.) ;
Dimensions 30 cm. +
Accompanying material 1 CD-ROM
502 ## - DISSERTATION NOTE
Dissertation note Project paper (Bachelor of Mechanical Engineering)-- Universiti Malaysia Pahang - 2013
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliography : p. 46-47
520 3# - SUMMARY, ETC.
Summary, etc. The increase on the usage of non-renewable energy has caused high demanding on energy supplies. This demand is highly needed for the industrial, transportation, domestic usage and etc. Shortage in the non-renewable energy had caused human to find other alternatives to generate energy. Hence, this research is aim to develop a flume, that later use to generate electricity. However, researcher only focuses on the design and analysis of the piping system of the flume. The objectives of this research is to design piping system of an open channel with less head losses and simulate it using CFD for only single phase perform (not free service), to evaluate the pressure drop in the pipes and to analyses and determine the head losses in the pipe. The instrument used is Solid Work 2012 for technical drawing of the piping system and Computational Fluid Dynamics (CFD) for simulation of the design and analysis. There are four designs of piping system that had been produce which is Design A, Design B, Design C and Design D, the properties measured for all four designs are pressure drop, percentage pressure drop, head loss and velocity. Design A; average percentage of pressure drop is 40.2%, average head loss which is 2.7 m, velocity; inlet velocity is 8.84 m/s and average outlet velocity is 8.75 m/s. Design B; average percentage of pressure drop is 53.6 %, average head loss which is 5.8 m, velocity; inlet velocity is 8.84 m/s and average outlet velocity is 14.31 m/s. Design C; percentage of pressure drop is 38.4 % ,head loss which is 4.4 m, velocity; inlet velocity is 8.84 m/s and outlet velocity is 11.76 m/s. Designs D; percentage of pressure drop is 30.7%, head loss which is 3.1 m, velocity; inlet velocity is 8.84 m/s and outlet velocity is 12.03 m/s. The best design is determined by less percentage of pressure drops, hence from the research findings Design D is the best design since it has the less percentage of pressure drop.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Flumes
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Renewable energy sources
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
  Not lost   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   TJ808.6 .H36 2013 r Bc. 0000086236 04/09/2019 1 04/09/2019 Final Year Report
  Not lost   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   CD 8059 | TJ808.6 .H36 2013 r Bc. 0000086237 04/09/2019 1 04/09/2019 Final Year Report

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us