Design of lightweight concrete arch tiles as permanent formwork for upper floor slab by using polystyrene beads / (Record no. 6021)

MARC details
000 -LEADER
fixed length control field 03553ntm a2200289 a 4500
001 - CONTROL NUMBER
control field vtls000092173
003 - CONTROL NUMBER IDENTIFIER
control field KUKTEM
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251117113259.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 151120t2015 my da f abm 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0000639(Local)
039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE]
Level of rules in bibliographic description 201905161126
Level of effort used to assign nonsubject heading access points nazirah
Level of effort used to assign subject headings 201711301155
Level of effort used to assign classification fateeha
-- 201511201155
-- asma
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) FKASA .N877 2015 r Bc.
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Nurshamiera Muhamad Fudzi
245 10 - TITLE STATEMENT
Title Design of lightweight concrete arch tiles as permanent formwork for upper floor slab by using polystyrene beads /
Statement of responsibility, etc. Nurshamiera Muhamad Fudzi
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Kuantan, Pahang :
Name of publisher, distributor, etc. UMP,
Date of publication, distribution, etc. 2015
300 ## - PHYSICAL DESCRIPTION
Extent xiii, 54 p. :
Other physical details ill. (some col.) ;
Dimensions 30 cm. +
Accompanying material 1 CD ROM
500 ## - GENERAL NOTE
General note Faculty of Civil Engineering and Earth Resources
502 ## - DISSERTATION NOTE
Dissertation note Project Paper (Bachelors of Civil Engineering) -- Universiti Malaysia Pahang – 2015
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliography : p. 47-49
520 3# - SUMMARY, ETC.
Summary, etc. Nowadays in Malaysia, many contractors and developers are still struggling to catch up with the current pace of development, especially in meeting country's demand, as conventional construction methods still work. Although traditional practice, this conventional method has several disadvantages such as high labor and material costs, and especially, a tendency not to change production of construction waste. Therefore, to overcome these weaknesses, permanent formwork using lightweight concrete is chosen as an alternative solution. In short, the new technology existence in construction to overcome this problem is permanent formwork using lightweight concrete which is more useful than conventional methods in terms of effectiveness of the functions, lighter, safety features and productivity. The main objective of this study is to determine the density and compressive strength of lightweight concrete to be used as arch slab by using polystyrene beads. The tests will be conducted is to find compressive strength and the displacement of the arch slab. All the procedures are prepared accordingly, to assure the research objectives are applicable, and to secure proper sequence and smooth running of the entire flow, from start until end. Six samples will provided, which three of them are 50mm and the rest is 75mm. All six samples of the slab tile are concreted at Heavy Structure Laboratory, Universiti Malaysia Pahang (UMP) and compressive strength test also conducted at same laboratory. Meanwhile the flexural test is conducted at Tensile Laboratory. From the theoretically calculation of arch tile of 50mm arch rise have highest horizontal and vertical force compared than arch rise 75mm with difference average load 1.267kN. While displacement of arch rise 50mm have highest displacement compared than arch tile of 75mm with difference displacement 0.463mm because of its geometry. Meanwhile, the density of fresh concrete with and without EPS also has difference about 68 kg/m3. As conclusion, EPS can be used as extenuating agent in concrete. However, from the observation, we can hardly distinguish which of this arch tile is stronger. Besides that, the development of the graph pattern for each sample is not consistent, thus explains the indifferences of the load bearing capacity
610 20 - SUBJECT ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Faculty of Civil Engineering and Earth Resources
General subdivision Dissertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Universities and Colleges
General subdivision Dissertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Theses
856 40 - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://ecollib.ump.edu.my/id/eprint/25245">http://ecollib.ump.edu.my/id/eprint/25245</a>
Public note Access in library only
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
  Not lost   Not for loan UMPLIB GAMBANG UMPLIB GAMBANG 04/09/2019   FKASA .N877 2015 r Bc. 0000104450 04/09/2019 1 04/09/2019 Final Year Report
  Not lost   Not for loan UMPLIB GAMBANG UMPLIB GAMBANG 04/09/2019   CD 9257 | FKASA .N877 2015 r Bc. 0000104451 04/09/2019 1 04/09/2019 Final Year Report

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us