MARC details
| 000 -LEADER |
| fixed length control field |
03239ntm a2200265 a 4500 |
| 001 - CONTROL NUMBER |
| control field |
vtls000092868 |
| 003 - CONTROL NUMBER IDENTIFIER |
| control field |
KUKTEM |
| 005 - DATE AND TIME OF LATEST TRANSACTION |
| control field |
20251117113309.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
| fixed length control field |
151203t2015 my da f abm 000 0 eng d |
| 020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
| International Standard Book Number |
THE0005532(Local) |
| 039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE] |
| Level of rules in bibliographic description |
201905161049 |
| Level of effort used to assign nonsubject heading access points |
hanafiah |
| Level of effort used to assign subject headings |
201710091214 |
| Level of effort used to assign classification |
aishah |
| -- |
201512031614 |
| -- |
asma |
| 040 ## - CATALOGING SOURCE |
| Original cataloging agency |
UMP |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) |
R857.C63 M37 2015 r Thesis |
| 100 0# - MAIN ENTRY--PERSONAL NAME |
| Personal name |
Mas Ayu Hassan |
| 245 10 - TITLE STATEMENT |
| Title |
Effects of hydroxyapatite coating with oxide interlayer on bioactivity performances in CoCrMo alloy / |
| Statement of responsibility, etc. |
Mas Ayu Hassan |
| 260 ## - PUBLICATION, DISTRIBUTION, ETC. |
| Place of publication, distribution, etc. |
Skudai, Johor : |
| Name of publisher, distributor, etc. |
UTM, |
| Date of publication, distribution, etc. |
2015 |
| 300 ## - PHYSICAL DESCRIPTION |
| Extent |
xviii, 141 p. : |
| Other physical details |
ill. (some col.) ; |
| Dimensions |
30 cm. + 1 CD ROM |
| 502 ## - DISSERTATION NOTE |
| Dissertation note |
Thesis (Doctor of Philosophy (Mechanical Engineering)) -- Universiti Teknologi Malaysia – 2015 |
| 504 ## - BIBLIOGRAPHY, ETC. NOTE |
| Bibliography, etc. note |
Bibliography : p. 117-126 |
| 520 3# - SUMMARY, ETC. |
| Summary, etc. |
Cobalt-chromium-molybdenum (Co-Cr-Mo) alloys have been reported difficult to bond directly on hard tissues owing to encapsulation by fibrous tissues. Several attempts have been made to improve the situation including coating with a bioactive layer which is mainly hydroxyapatite (HA). Various HA coating methods have been introduced but massive micro crack surface, delamination and low adhesion strength of HA coating are still the major concerns that cause the harmful release of metal ions. In this study, an oxide interlayer on Co-Cr-Mo alloys was developed through thermal oxidation prior to HA coating with the objective to provide better anchorage of HA coatings on the substrate surface, reduce metal ions release and at the same time enhancing the cell attachment. The thermal oxidation process was conducted in a muffle furnace at different temperatures (850°C, 1050°C and 1250°C) for 3 hours to create an oxide interlayer on the substrate surface. It was followed by coating HA on the bare material and on the oxidized substrates using sol gel dip coating technique. Scratch test results showed that the bonding strength of the HA on the oxide interlayer is markedly higher than the HA coated substrates without oxide interlayer. It seems that rough surface of oxide interlayer provides better mechanical interlocking of HA particles to the substrate surface. Inductively coupled plasma-mass spectrometry (ICP-MS) test illustrated that the release of Co and Cr ions from the HA coated oxidized substrates reduced significantly after 28 days immersion as compared to bare material and HA coated substrates without oxide interlayer. This indicates that oxide interlayer is able to act as an additional barrier to suppress the metal ions release. Similarly, the HA coated substrates with oxide interlayer demonstrate strong attachment and proliferation of cells than the HA coated substrates without oxide interlayer. It is concluded that the introduction of an intermediate oxide layer on Co-Cr-Mo substrate prior to HA coating has shown a positive effect in terms of increment of the adhesion strength of HA coating as well as cell bioactivity performance |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Cobalt-chromium-nickel alloys |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Biomedical materials |
| 856 40 - ELECTRONIC LOCATION AND ACCESS |
| Uniform Resource Identifier |
<a href="http://ecollib.ump.edu.my/3566/">http://ecollib.ump.edu.my/3566/</a> |
| Public note |
Library access only |