Strengthening of reinforced concrete deep beams having large square openings in shear zone with carbon fiber reinforced polymer (CFRP) wrap / (Record no. 6442)

MARC details
000 -LEADER
fixed length control field 03646ntm a2200289 a 4500
001 - CONTROL NUMBER
control field vtls000092090
003 - CONTROL NUMBER IDENTIFIER
control field KUKTEM
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251117113314.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 151118t2015 my da f abm 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0000600(Local)
039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE]
Level of rules in bibliographic description 201905161017
Level of effort used to assign nonsubject heading access points nazirah
Level of effort used to assign subject headings 201711291550
Level of effort used to assign classification fateeha
-- 201511180950
-- asma
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) FKASA .N45 2015 r Bc.
100 1# - MAIN ENTRY--PERSONAL NAME
Personal name Ng, Kin Mun
245 10 - TITLE STATEMENT
Title Strengthening of reinforced concrete deep beams having large square openings in shear zone with carbon fiber reinforced polymer (CFRP) wrap /
Statement of responsibility, etc. Ng Kin Mun
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Kuantan, Pahang :
Name of publisher, distributor, etc. UMP,
Date of publication, distribution, etc. 2015
300 ## - PHYSICAL DESCRIPTION
Extent xvi, 71 p. :
Other physical details ill. (some col.) ;
Dimensions 30 cm. +
Accompanying material 1 CD ROM
500 ## - GENERAL NOTE
General note Faculty of Civil Engineering and Earth Resources
502 ## - DISSERTATION NOTE
Dissertation note Project Paper (Bachelors of Civil Engineering) -- Universiti Malaysia Pahang – 2015
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliography : p. 67-70
520 3# - SUMMARY, ETC.
Summary, etc. Typically, the reinforced concrete (RC) deep beam with large openings are facing some severe problems such as the interruption of natural load transfer by concrete struts acting in compression which can cause an intensive reduction in strength; and the clearly visible cracks in serviceability conditions. The CFRP has become an alternative solution to this issue and being extensively used as an external reinforcement to resolve the strength requirements in structural systems due to extremely strong yet light weight, outstanding fatigue properties, excellent corrosion resistance and easy yet efficient application on concrete. This experimental study is focuses on the investigation of the effect of CFRP wrap in strengthening RC deep beams with large square openings located in shear zone. Three approaches are under consideration; the first is the determination of natural load transfer in normal deep beam without opening, the second is the large square openings in deep beam without CFRP strengthening, and the third is the large square openings in deep beam with CFRP attached around the openings. A total of four RC deep beams which included a solid RC control beam, a deep beam with two large square openings, and two beams with two large square openings strengthened by using CFRP strips in different strengthening configurations, were tested to failure under four point loading to determine the relative structural behaviour such as ultimate load, failure mode, crack patterns, and load deflection behaviour. All RC deep beams were designed in a dimension of 120 x 600 mm and 2400 mm in length. The width and height of large square openings were in a dimension of 270 x 270 mm and located 300 mm from the edge of the deep beam. The loading point and support were located at 800 mm and 300 mm from the edge of the deep beam, respectively. RC deep beam with large square openings, US-BSO was significantly reduced the beam capacity by 61.76 % as compared to solid control beam, CB. However, the RC deep beam with large square openings strengthened by CFRP strips wrapped in U-shaped, SU-BSO has increases the beam capacity by 62.77 % compared to US-BSO. From the results obtained, it was found that the most effective CFRP strengthening method for RC deep beam with large square openings was U-shaped, which recovered the beam capacity up to 62.24 % as compared to solid control beam
610 20 - SUBJECT ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Faculty of Civil Engineering and Earth Resources
General subdivision Dissertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Universities and Colleges
General subdivision Dissertations
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Theses
856 40 - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://ecollib.ump.edu.my/id/eprint/24913">http://ecollib.ump.edu.my/id/eprint/24913</a>
Public note Access in library only
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
  Not lost   Not for loan UMPLIB GAMBANG UMPLIB GAMBANG 04/09/2019   FKASA .N45 2015 r Bc. 0000104402 04/09/2019 1 04/09/2019 Final Year Report
  Not lost   Not for loan UMPLIB GAMBANG UMPLIB GAMBANG 04/09/2019   CD 9234 | FKASA .N45 2015 r Bc. 0000104403 04/09/2019 1 04/09/2019 Final Year Report

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us